Monessen Hearth BDV300, BDV600, BDV500 Venting Installation, Rear Through the Wall Applications

Models: BDV400 BDV500 BDV300 BDV600

1 52
Download 52 pages 34.58 Kb
Page 18
Image 18

VENTING INSTALLATION

REAR (THROUGH THE WALL) APPLICATIONS

When installed as a rear vent unit this appliance may be vented directly to a termination located on the rear wall behind the appliance

The maximum horizontal distance between the rear of the appliance and the outside of termination is 20" (508 m). See Figure 14.

Only one 45° elbow is allowed in these installations.

Maximum 20"

Top View Flat Installation

Figure 14 - Rear Vent Application,

Maximum Horizontal Distance

Sealant is not required to assemble BDV/DVB fireplace venting. Do not use silicone sealant at the flue exhaust connections.

1.Find the pipe section’s direction label. The label arrow shall be pointed away from the firebox and toward the termination. Firmly insert the initial rigid section/elbow into the firebox outer collar. Simpson “GS” and Selkirk “DT” outer walls are hemmed and will snap into the collar’s tabs. Attach Simpson’s Direc- tVent Pro by fully inserting into the collar and securing with self tapping screws. The screws shall only penetrate the flue outer wall.

Refer to vent manufacturer’s installation instructions to properly assemble flue.

2.Locate and cut the vent opening in the wall. For combustible walls first frame in opening.

Combustible Interior Walls: Cut a 111￿2"H x 91￿2" W hole through the interior wall.

Combustible Exterior Walls: Cut a 91￿2"H x 91￿2"W square hole through the exterior wall frame. See Figure 16.

Noncombustible Walls: Hole opening should be 71￿2" (190mm) in diameter.

3.The center of the hole should line up with the center line of the horizontal rigid vent pipe end. Pipe shall always run level or uphill on horizontal runs. Never run pipe down hill. See Figure 16.

Female

Locking Lugs

Note: Horizontal runs of vent must be supported every three feet (914mm). Use wall straps for this purpose.

Male Slots

Figure 15 - Rigid Vent Pipe Connections

91/2"

(241mm)

91/2"

(241mm) 33/4"

(92mm)

71/2"

(190mm)

Figure 16 - Exterior Wall Framing Dimensions

18

54D0700

Page 18
Image 18
Monessen Hearth BDV300, BDV600, BDV500, BDV400 operating instructions Venting Installation, Rear Through the Wall Applications