CLEARANCES and HEIGHT REQUIREMENTS
| 12" |
| 10" |
| 8" |
6" | 23" |
| |
21/2" | 21" |
19" | |
| 16" |
| 12" |
4.Mantel clearances: The canopy supplied with the unit must be installed. If a combustible mantel is installed, it must meet the clearance requirements as shown in Figure 5.
Figure 5 - Mantel Clearances
5.Floor clearance: This inner chamber firebox floor must be installed at least 5" above any combustible flooring material, such as carpeting or asphalt tile, which is closer than 14" to the base of the firebox. See Figure 6.
Or
The inner chamber firebox floor may be installed nearer to the floor if a minimum of 14" of noncombustible material such as slate or marble is installed between the base of the firebox and the combustible flooring. See Figure 7.
| Can Be | |
Less than 5" | ||
| Material | |
Material |
| |
|
| |
5" Minimum |
|
|
| 14" Minimum |
|
| Figure 7 - Minimum Clearance above Combustible | |
Figure 6 - Minimum Clearance above | Flooring with | |
Combustible Flooring | Base of Fireplace |
61D1013