FIRESTOP THIMBLE AND THIMBLE EXTENSION (CONTINUED)

CHIMNEY INSTALLATION

FIRESTOP THIMBLE AND THIMBLE EXTENSION (CONTINUED)

3.For unventilated cathedral type ceiling on double-wide manufactured homes, the firestop thimble should extend through both the ceiling and roof structures. See Figure 15.

SVTR Firestop Thimble May Be

Trimmed Off Flush with Roof Line if

It interferes with Flashing

SVTR Firestop Thimble

(Swivels 0 to 15°)

• 7 ½° Pitch Requires 14½" x 14¾" Framed Opening

• 15° Pitch Required 14½" x 15" Framed Opening.

Figure 15 - Unvented Cathedral Type Ceiling

4.Install first chimney section by inserting the male end of the flue (the smallest diameter pipe) into the flue collar of the fireplace. Press down until the snap locks engage. Place the female end of the 11" diameter pipe on top of the fireplace and press down until the snap locks engage. Continue this process, until the chimney is at least 8" to 16" above the roof opening for installation of the Model SC Chimney Cap later. At this point, the chimney must not exceed 13½' road clearance. This will allow the top section of chimney and chimney cap or chimney housing to be removed for moving the manufactured home on the highway.

Note: If additional strength of the outer pipe joints is desired, place (2) or three (3) sheet metal screws through the area where the outer pipes overlap one another. Install these screws by drilling a 1/8" diameter hole through the chimney sections.

WARNING

Be very careful when drilling holes into outer pipe. The drill must not penetrate the inner stainless steel pipe.

5.Make sure all joints of the chimney are tight. Check clearance between the chimney and combustible materials before proceeding with installation of the roof flashing and chimney cap.

16

61D0087

Page 16
Image 16
Monessen Hearth BWBC400MHB, BWBC500MHB manual Chimney Installation, Firestop Thimble And Thimble Extension Continued