Monessen Hearth BWBC500MHB Figures 3 and, How This Fireplace Works, Correct Position, by Figure

Models: BWBC500MHB BWBC400MHB

1 40
Download 40 pages 58.86 Kb
Page 7
Image 7
Figure 3 - Correct Position

HOW THIS FIREPLACE WORKS

For large fires, the maximum heating benefit from the fireplace will be

Fireplace

obtained with its glass doors fully open. The open doors will allow more

 

radiant heat to be emitted out of the front opening of the fireplace. When

 

the glass doors are open, close the fireplace’s mesh screens

 

to help keep burning embers from popping out of the firebox.

 

With a small fire, it is best to operate the fireplace with its glass doors

 

fully closed to prevent excessive room air from being drawn up the

Glass Doors Fully Open

chimney. To prevent room air from escaping up the chimney overnight,

 

close the fireplace glass doors before retiring in the evenings.

 

Figure 3 - Correct Position

 

 

 

 

 

 

Fireplace

WARNING

The fireplace should be operated only with

 

its glass doors fully open or fully closed. If

Do not

 

 

glass doors are left partially open, gas and

 

operate

 

flame may be drawn out of fireplace opening.

 

fireplace like

 

This creates risks of both fire and smoke. See

 

this!

 

Figures 3 and 4.

 

 

 

Glass Doors Partially

 

 

 

 

 

 

Open

With the provided AK6A combustion air kit installed on the

 

Figure 4 - Incorrect Position

 

 

fireplace, outside combustion air may enter the firebox through

Air Combustion Control Lever

a dampered opening located on the left side of the fireplace.

 

 

This feature reduces the room air used for combustion and

 

 

prevents excessive heat loss from the room. When the fire-

 

 

place is in use, this damper should be open. When the

 

 

fireplace is not in use, the damper may be closed to prevent

 

 

cold air from entering the firebox. The outside combustion

 

 

air control lever is located inside the fireplace firebox just

 

 

above the brick panel on the left side of the firebox as shown

 

 

by Figure 5.

 

 

NOTE: Outside combustion air damper is open when its control lever is up. The damper is closed when its control lever is down.

The fireplace must be supplied with outside combustion air when the fireplace is installed in a manufactured home. See the Outside Combustible Air section of this manual for additional information about outside combustion air.

This fireplace is equipped with a factory-installed fan assem- bly to help circulate heat produced by the fireplace. The fanʼs ON/OFF rocker switch is installed in the left side of the lower louver panel on the front of the fireplace. Use the ON/OFF rocker switch to turn the fan on and off as desired for heat circulation. See the Wiring for Fan Assembly, page 27 of this manual for additional information about fan assembly.

Figure 5 - Outside Combustion Air Control Lever Location

61D0087

7

Page 7
Image 7
Monessen Hearth BWBC500MHB manual Figures 3 and, How This Fireplace Works, Correct Position, Incorrect Position, by Figure