Monessen Hearth BWBC500MHB, BWBC400MHB Fan Assembly, Locating Mantel, See Figure, Wiring Diagram

Models: BWBC500MHB BWBC400MHB

1 40
Download 40 pages 58.86 Kb
Page 23
Image 23
LOCATING MANTEL

TRIM AND MANTEL INSTALLATION FOR WOOD BURNING FIREPLACES

LOCATING MANTEL

Maximum depth of mantel is 12"

A =

6½" -

Minimum from top of fireplace opening to bottom

 

 

of any combustible trim material sticking out no

 

 

more than 1½" beyond face of fireplace

B =

12" -

Minimum from top of fireplace opening to bottom

 

 

of combustible trim material sticking out more than

 

 

1½" from top of fireplace opening

Combustible

Combustible

 

Wall Board

Mantel

 

 

12"max.

Non-

 

 

 

Combustible

 

Surround Trim

 

B

 

 

A

 

 

Top of

 

 

Fireplace

 

 

Opening

 

Figure 25 - Locating Mantel

FAN ASSEMBLY

This fireplace is equipped with a fan assembly to help circulate heat pro-

 

duced by the fireplace. The energy used by the fan assembly will be less

WARNING

receptacle box (field-wired) to a 60 Hz, 120 vac, 15 amp electrical circuit.

than a 30 watt light bulb.

 

The fan assembly has been factory-wired to the fireplace receptacle box

 

located on the right side of the fireplace. Connect wiring from the fireplace

 

Field-wiring must comply with local codes or, in the absence of local

 

codes, with the latest edition of National Electrical Code ANSI/NFPA 70.

 

See Figure 26.

 

Fireplace

Receptacle Box

Fan

Fan

 

Motor

Motor

 

1

2

Cord Set

 

 

120V, 60Hz

Ground

On/Off

Rocker Switch

(SPST)

Figure 26 - Wiring Diagram

Always check and make sure power is off before attempting to install or service any electrical wiring or components.

Field Wire to

60Hz, 120 VAC, 15AMP Electrical Circuit

61D0087

23

Page 23
Image 23
Monessen Hearth BWBC500MHB, BWBC400MHB manual Fan Assembly, Locating Mantel, See Figure, Wiring Diagram