TRIM AND MANTEL INSTALLATION FOR WOOD BURNING FIREPLACES
LOCATING MANTEL
Maximum depth of mantel is 12"
A = | 6½" - | Minimum from top of fireplace opening to bottom |
|
| of any combustible trim material sticking out no |
|
| more than 1½" beyond face of fireplace |
B = | 12" - | Minimum from top of fireplace opening to bottom |
|
| of combustible trim material sticking out more than |
|
| 1½" from top of fireplace opening |
Combustible | Combustible |
|
Wall Board | Mantel |
|
| 12"max. | Non- |
|
| |
| Combustible | |
| Surround Trim | |
| B |
|
| A |
|
| Top of |
|
| Fireplace |
|
| Opening |
|
Figure 25 - Locating Mantel
FAN ASSEMBLY
This fireplace is equipped with a fan assembly to help circulate heat pro- |
|
duced by the fireplace. The energy used by the fan assembly will be less | WARNING |
receptacle box | |
than a 30 watt light bulb. |
|
The fan assembly has been |
|
located on the right side of the fireplace. Connect wiring from the fireplace |
|
| |
codes, with the latest edition of National Electrical Code ANSI/NFPA 70. |
|
See Figure 26. |
|
Fireplace
Receptacle Box
Fan | Fan |
|
Motor | Motor |
|
1 | 2 | Cord Set |
|
| 120V, 60Hz |
Ground
On/Off
Rocker Switch
(SPST)
Figure 26 - Wiring Diagram
Always check and make sure power is off before attempting to install or service any electrical wiring or components.
Field Wire to
60Hz, 120 VAC, 15AMP Electrical Circuit
61D0087 | 23 |