Monessen Hearth CFX32, CFX24 manual Connect The Gas, check gas type, Installation Items Needed

Models: CFX24 CFX32

1 36
Download 36 pages 45.17 Kb
Page 15
Image 15
CONNECT THE GAS

CONNECT THE GAS

CFX Vent Free Fireplace System

check gas type

 

Use proper gas type for the fireplace you are installing. If you have conflicting gas type, do not install fireplace. See dealer where you purchased the fireplace for proper fireplace for your gas type or conversion kit.

Installing gas piping to fireplace / burner system location

WARNING

A qualified installer or service person must connect appliance to gas supply. Follow all local codes.

CAUTION

For propane/LP units, never connect fireplace directly to the propane/LP supply. This burner system requires an external regulator (not supplied). Install the external regulator between the burner system and propane/LP supply.

INSTALLATION ITEMS NEEDED

Before installing fireplace and burner system, make sure you have the items listed below.

External regulator

Piping (check local codes)

Sealant (resistant to propane/LP gas)

 

(supplied by installer)

Equipment shutoff valve*

Test gauge connection*

Sediment trap (recommended)

Tee joint

Pipe wrench

approved flexible gas line with gas connector (if allowed by local codes — not provided)

*A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge con- nection. Purchase the CSA design-certified equipment shutoff valve from your dealer.

For propane/LP connections only, the installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 13 inches of water. If you do not reduce incoming gas pressure, burner system regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 13. Pointing the vent down protects it from freezing rain or sleet.

 

100 gallon (min)

External

Propane/LP Supply

Tank

Regulator

 

 

Vent Pointing

 

Down

 

FP1977

 

Use only new black iron or steel pipe.

 

Internally tinned copper or copper tubing

CAUTION

can be used per National Fuel Code, Section

2.6.3, providing gas meets hydrogen sulfide

 

 

limits, and where permitted by local codes.

 

Gas piping system must be sized to provide

 

minimum inlet pressure (listed on data

 

plate) at the maximum flow rate (BTU/hr).

 

Undue pressure loss will occur if the pipe

 

is too small.

 

 

When using copper of flex connectors use only fittings approved for gas connections. The gas control inlet is 3/8" NPT.

Figure 13 -

External Regulator with Vent Pointing Down (Propane/LP Only)

20301726

15

Page 15
Image 15
Monessen Hearth CFX32, CFX24 Connect The Gas, check gas type, Installation Items Needed, CFX Vent Free Fireplace System