ELECTRICAL WIRING (Milli-volt)

CFX Vent Free Fireplace System

Connect Remote Receiver

THESE INSTRUCTIONS SUPERSEDE THE SECTION ENTITLED “HEARTH MOUNT” IN THE MILLI-VOLT HAND-HELD REMOTE INSTRUCTIONS SUPPLIED WITH THE REMOTE.

1.Remove bottom louver door.

2.Connect the remote connectors located in the unit.

3.Apply Velcro® pads with self-adhesive backing to bottom of remote receiver and to floor of compart- ment behind access panel.

4.Attach remote receiver to firebox with Velcro® pads. Control switch must face forward.

Velcro® Pad

SKYTECH

OFF

 

FIREPLACE

REMOTE

REMOTE

 

ON

 

 

Remote Receiver

Figure 17 -

Velcro Pad

NOTICE

Install Remote Receiver

FP2113

Do not place remote in combustion chamber.

Check System Operation

The millivolt system and individual components may be checked with a millivolt meter having a 0-1000 mV range. Conduct each check shown in chart below by connection meter test leads to terminals as indicated.

 

 

Connect Meter

Switch or

Meter

Check

To

Leads to

Thermostat

Reading

Test

Test

Terminals

Contacts

Should Be

A

Complete

2 & 3

Closed

Closed

 

System

 

 

 

B

Thermopile

1 & 2

Open

Open

 

Output

 

 

 

 

 

 

 

 

A.Complete Millivolt System Check

(“A” Reading - Thermostat contacts CLOSED - Control Knob “ON” - Main burner should be come ON)

a.If the reading is more than 100 millivolts and the automatic valve still does not come on, replace the control.

b.If the closed circuit reading (“A” reading) is less than 100 milli-volts, determine cause for low read- ing, proceed to Section B below.

B.Thermopile Output Reading Check

(“B” Reading - Thermostat contacts OPEN - Main burner OFF)

1. Check gas pressure to the unit. If gas pressure is within minimum and maximum on data plate, then check pilot voltage, 325 millivolts minimum. If the minimum milli-volt reading is not obtainable, replace pilot.