LOG & ROCKWOOL PLACEMENT | CFX Vent Free Fireplace System |
Proper installation sequence | Rear Log | ||
#3 | |||
(CFX32) | |||
| |||
Figure 19 |
| ||
1. | Install front right log (#1) on two pins on right Left Middle | ||
| side of burner. | Log #5 | |
2. | Install left front log (#2) on two pins on left side |
| |
| of burner. |
| |
3. | Install back log (#3) on back of burner. |
| |
4. | Install right middle log (#4) on two pins on |
| |
| burner. Rest right end of right middle log on | Left Front | |
| the right front log. | Log #2 |
5. Install left middle log (#5) on two pins on burner. Rest left end of left middle log on left front log.
Pins
Pins
Figure 19 -
Log Placement CFX32
Right Middle Log #4
Right Front Log #1
Pins
Pins
LG589
Place rock wool
After installing logs, pull apart
Dime Size Rock
Wool
CAUTION
•Use only rock wool provided with log set.
•Do not add additional rock wool.
•Place rock wool on burner ports only.
•Keep air gap between rear log and burner
CLEAN.
Figure 20 -
Rockwool Installation
LG590
20301726 | 21 |