Monessen Hearth CFX32 Log & Rockwool Placement, Proper installation sequence, Place rock wool

Models: CFX24 CFX32

1 36
Download 36 pages 45.17 Kb
Page 21
Image 21
LOG & ROCKWOOL PLACEMENT

LOG & ROCKWOOL PLACEMENT

CFX Vent Free Fireplace System

Proper installation sequence

Rear Log

#3

(CFX32)

 

Figure 19

 

1.

Install front right log (#1) on two pins on right Left Middle

 

side of burner.

Log #5

2.

Install left front log (#2) on two pins on left side

 

 

of burner.

 

3.

Install back log (#3) on back of burner.

 

4.

Install right middle log (#4) on two pins on

 

 

burner. Rest right end of right middle log on

Left Front

 

the right front log.

Log #2

5. Install left middle log (#5) on two pins on burner. Rest left end of left middle log on left front log.

Pins

Pins Proper installation sequence

Figure 19 -

Log Placement CFX32

(CFX32) Right Middle Log #4

Figure 19 Right Front Log #1

Pins

Pins

LG589

Place rock wool

After installing logs, pull apart dime-size pieces of rock wool. Place rock wool evenly over burner ports. Wash hands after installing rock wool. Itching may occur.

Dime Size Rock

Wool

CAUTION

Use only rock wool provided with log set.

Do not add additional rock wool.

Place rock wool on burner ports only.

Keep air gap between rear log and burner

CLEAN.

Figure 20 -

Rockwool Installation

LG590

20301726

21

Page 21
Image 21
Monessen Hearth CFX32, CFX24 manual Log & Rockwool Placement, Proper installation sequence, Place rock wool