4 DIAGNOSTICS

Interactive Status

This diagnostic describes the interactive information that is displayed only when the Thin Client platform is running. The information on the OSD and front panel is updated at least once every 5 seconds while the diagnostic is displayed. This is an example of a code module display with status descriptions:

Figure 4-10 Interactive status front panel display

The Interactive Status fields are:

Field

Description

 

 

 

 

 

IP Address

The IP address in dotted-decimal format xxx.xxx.xxx.xxx assigned by the NC 1500 to the

 

DCH3416. 0.0.0.0 is displayed if the IP address is not configured or unknown.

 

 

 

 

UPM

The upstream modem address value is the same as the terminal ID assigned by the

 

DAC 6000. It is a unique, system-generated, eight-digit integer between 1 and 16777215.

 

00000000 is displayed when the UPM is not configured or if it is unknown.

 

 

 

 

Upstream ID

A four-digit decimal value from 0000 to 9999 assigned by the DAC 6000 to the DCH3416.

 

0000 is displayed if the Upstream ID is not configured or if it is unknown.

 

 

 

 

Downstream

A four-digit decimal value from 0000 to 9999 assigned by the DAC 6000 to the DCH3416.

ID

0000 is displayed if the Downstream ID is not configured or if it is unknown.

 

 

 

 

State

The interactive status of the DCH3416:

 

 

 

 

 

Front

OSD

Description

 

Panel

 

 

 

 

 

 

 

U

UNCONFIG

The DCH3416 is not configured for the interactive system,

 

 

 

and the platform should run as pre-interactive.

 

 

 

 

 

C

MAC_CONNECT

The DCH3416 is waiting to establish a connection to the

 

 

 

MAC PID Stream.

 

 

 

 

 

 

 

56