12 - 2 Symbol MS4404/MS4407 Integration Guide

Errors While Imaging
Unless otherwise specified, to correct an error during an imaging sequence, just re-capture the correct parameter.
Miscellaneous Imager Parameter Defaults
Table 12-1 lists the defaults for miscellaneous imager options. To change any option, capture the appropriate bar
code(s) provided in the Miscellaneous Imager Parameters on page 12-3.
NOTE See Appendix A, Standard Defaults for all user preferences, hosts, symbologies, and miscellaneous
default parameters.
Table 12-1
Miscellaneous Imager Options Default Table
Parameter Parameter
Number Default Page
Number
Transmit Code ID Character 2Dh None 12-3
SSI Prefix Value 69h <CR> 12-4
SSI Suffix 1 Value
SSI Suffix 2 Value 68h
6Ah <CR>
<CR> 12-4
Non-SSI Prefix Value 63h, 69h <CR><LF> 12-4
Non-SSI Suffix 1 Value
Non-SSI Suffix 2 Value 62h, 68h
64h, 6Ah <CR><LF>
<CR><LF> 12-4
Scan Data Transmission Format EBh Data as is 12-5
FN1 Substitution Values 67h, 6Dh Set 12-6
Transmit “No Read” Message 5Eh Disable 12-7