Fiber Driver

EM316E3 & EM316E3SF

f)ESD protective floor or mat: The mat must be grounded through a current- limiting resistor. The floor or mat dissipates the static charge of personnel approaching the workbench. Special conductive tile or floor treatment can be used when mats are not practical or cause a safety hazard. Chairs should be conductive or grounded with a drag chain to the flooring.

STEP 2 Determine the best location for the chassis.

Affix the chassis to a 19” or 23” rack using the enclosed rack mount ears, or place the unit on a secure, flat surface. Ensure that the unit is within reach of the necessary connections (i.e. power outlet, Ethernet connections, and, if the chassis will be monitored via serial port, and either a PC, UNIX workstation, or modem).

STEP 3 Make sure there is enough space to pull and connect both the electrical and optical cables without stressing them beyond the manufacturer’s limitation (bend radius minimum).

STEP 4 Plug in the chassis

Connect the power cord (s) to the chassis and an outlet. Turn the power switch (es) to ON position. The wide-ranging power supply adjusts to any outlet.

STEP 5 Unpacking the unit

Verify that no visible damage has been caused to the outer box. Remove all material from the packing box and confirm receipt of the following:

Fiber Driver module unit

User’s manual (this manual in printed format or on a CD)

In the unlikely event that anything is missing, contact your authorized dealer or representative. If it becomes necessary to return the unit, repackage the unit in its original box.

P/N: 1226006-001, REV_L

PAGE 12

Page 12
Image 12
MRV Communications EM316E3SF manual Determine the best location for the chassis, Unpacking the unit