Fiber Driver

EM316E3 & EM316E3SF

Configuration

Jumper Settings: (Factory Default)

 

 

CONFIGURING THE SWITCH (S1)

 

 

 

SWITCH

SETTINGS

RESULTS

 

 

 

MAN/NMS

*ON

Force switches selections (loop back) regardless of NMS command

 

 

OFF

Default setting comes from switches after power up, but maybe change by NMS

 

 

 

commands

SEC/PRI

ON/OFF

Not used in this application. Reserved for the dual-redundant card.

 

 

Setting is irrelevant to the card

LPBK/NORMA

ON

Loop back mode enabled

 

 

OFF

Normal mode enabled

L

 

 

LONG/SHORT

*ON

Cable length is longer than 250 feet

 

 

OFF

Cable length is shorter than 250 feet

 

 

 

 

SW5

ON/OFF

Setting is irrelevant to this card at this time

 

 

 

Note: LONG/SHORT settings shown above are the recommended setup, but can be change to other polarity if better results/performance can be achieved.

Default Setup: MAN/NMS, LONG/SHORT: ON. All other switches: OFF

ONOFF

5 FORCE / AUTO

4LONG/SHORT CX

3LPBK/NORMAL

2SEC/PRI

1MAN/NMS

1 2 3 4 5

ON

5

4

3

2

1

S1

IMPORTANT NOTICE

The jumper settings shown above should be use only on expansion modules that has printed circuit board assembly (PCBA) number: 1226062-007 or later. This number can be found on a white bar coded label located at the bottom side of the expansion module.

P/N: 1226006-001, REV_L

PAGE 8

Page 8
Image 8