Multi-Tech Systems MT2456SMI22 manual 22bis Line Side Device Commands, Response

Models: MT2456SMI22

1 58
Download 58 pages 21.39 Kb
Page 34
Image 34

Chapter 4 - V.22bis Commands

V.22bis Line Side Device Commands

-TTE

Threshold Adjustments for Telephony Extension

This command allows the host to set/tune the telephone line voltage level drop threshold necessary for the modem to determine Line-in-Use, Extension Pickup, and Remote Hangup conditions. An ATZ or AT&F will load default values.

Syntax

-TTE=<Line-in-Use voltage drop threshold>,<Extension Pickup voltage drop threshold>, <Remote Hangup voltage drop threshold>

Defined Values

Range =(0-9999), (0-9999), (0-9999) Units: 1/10 volt

<Line-in-Use voltage drop threshold>

default: 1000 (10.00 V drop while modem onhook) <Extension Pickup voltage drop threshold>

default: 200 (2.00 V drop while modem offhook) this value must be less than the Remote Hangup voltage drop threshold

<Remote Hangup voltage drop threshold>

default: 500 (5.00 V drop while modem offhook) this value must be greater than the Extension Pickup voltage drop threshold

AT-TTE? Queries current setting

Notes:

1.All thresholds are difference thresholds. Example: The line would be considered “in use” if the Tip & Ring Voltage

dropped by 10.00 volts. Another Example: If the modem is off hook and the voltage drops by more than 2.50 volts, then the modem would consider the condition as an extension pick up.

2.The <Remote Hangup voltage drop threshold> must always be less than the <Extension Pickup voltage drop threshold). Otherwise, the extension pickup will not function.

-TRV Tip and Ring Voltage Measurement

This command measures and reports the telephone line voltage level at Tip and Ring while on-hook or in off-hook command mode. If an application does not want to enable the telephony extension features through the –STE command, the voltage value may be obtained using the -TRV command instead. This is also a very useful debug command.

Syntax

-TRV

Defined Values

Units: Volts

Response

xx.yy Example: A value of 30.50 indicates 30.50 V.

OK The lowest value reported by the modem is 1.40 V based on conversion formula.

Multi-Tech Systems, Inc. MT2456SMI-22 SocketModem Developer’s Guide

34

Page 34
Image 34
Multi-Tech Systems MT2456SMI22 22bis Line Side Device Commands, Threshold Adjustments for Telephony Extension, Response