Multi-Tech Systems MT2834BL Series, MT2834BA Series To set parity of the password/message prompt

Models: MT2834BL Series MT2834BA Series

1 120
Download 120 pages 36.56 Kb
Page 71
Image 71

Chapter 7 - Callback Security and Remote Configuration

To turn your modem's Callback Security feature on and off:

7.If you want Callback Security with both remote and local password security, enter AT#DB1 and hit RETURN. You must turn on Callback Security to be able to enter dial back phone numbers.

8.If you want Callback Security on with just remote password security, enter AT#DB2 and hit RETURN. You must turn on Callback Security to be able to enter dial back phone numbers. If you want to use your modem to call another modem that is also set for Callback, you must enter AT#DB3 before you dial.

Note: this is for your modem if you are set for #DB1 or #DB2.

Once you have disconnected from that call, your modem will go back to its original setting.

9.If you want Callback Security turned off, type AT#DB0 and hit RETURN.

To set parity of the password/message prompt:

10.The parity default value for your modem is no parity (AT#P0). If your modem's prompt messages use even parity, enter AT#P2 and hit RETURN. For odd parity, enter AT#P1 and hit RETURN.

11.Enter the &W0 command and hit RETURN to store parameters and S-Register values in RAM.

Table 7-2. Callback Password and Dial Back Phone Number Entry Procedures

1.Enter your modem's LOGIN Password (as selected in Table 7-1) by entering the following: AT#Ixxxxxxxxxx<CR> (xxxxxxxxxx from Table 7-1)

Enter your modem's Setup Password (as selected in Table 7-1) by entering the following:

AT#Syyyyyyyyyy<CR>(yyyyyyyyyy from Table 7-1)

2.Enable the Callback Security feature by entering the following: AT#DB2<CR> or AT#DB1<CR>

The following message is displayed on your monitor:

Entering Callback Mode, current phone numbers will be erased. Do you want to continue? (Y/N)

3.Enter a Y or N and hit RETURN.

Note: If this is your first time into Callback Mode, we recommend answering Y to clear all previous Callback Passwords and phone numbers from memory.

4.Enter individual Callback Passwords for each of 30 different phone number memory locations as follows:

AT#CBN0xxxxxxxxxx<CR>

To enter Callback Password for the first location (a minimum 6 characters, up to a maximum of

10characters must be used).

AT#CBN1xxxxxxxxxx<CR>

To enter Callback Password for the second location...etc (a minimum 6 characters, up to a maximum of 10 characters must be used).

Note: The first character of your first Callback Password must be non-numeric.

5.Enter individual phone numbers for each of the 30 memory locations as follows: AT+ - DP...????N0 <CR> (number for location N0)

AT+ - DT...????N1 <CR> (number for location N1)...etc

Note: You must indicate within the command string that the modem either Pulse dial (ATDP...) or Tone dial ATDT...).

The maximum length of the number is 35 characters. The number may include commands as well as your number, so as to create macro-type command numbers.

Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide

71

Page 71
Image 71
Multi-Tech Systems MT2834BL Series, MT2834BA Series manual To set parity of the password/message prompt, AT#CBN0xxxxxxxxxxCR