DCA-400SSV— GENERATOR CONTROL PANEL

Also the engine controller will shut down the engine in the event of low oil pressure, high coolant temperature, low coolant level, and loss of magnetic pickup.These conditions can be observed by monitoring the LED status indicators on the front of the controller module.

A.MPEC Control Switch – This switch controls the running of the unit. If this switch is set to the OFF/RESET position, the unit will not run. When this switch is set to the MANUAL position, the generator will start immediately.

If the generator is to be connected to a building's AC power source via a transfer switch (isolation), place the switch in the AUTO position. In this position the generator will monitor the AC line output from the building's power source.

B.Low Oil Pressure – Indicates the engine pressure has fallen below 15 psi. The oil pressure is detected using variable resistive values from the oil pressure sending unit. This is considered a major fault.

C.High Coolant Temperature – Indicates the engine temperature has exceeded 239°F. The engine temperature is detected using variable resistive values from the temperature sending unit. This is considered a major fault.

D.Overcrank Shutdown – Indicates the unit has attempted to start a pre- programmed number of times, and has failed to start. The number of cycles and duration are programmable. It is pre-set at 3 cycles with a 10 second duration. This is considered a major fault.

E.Overspeed Shutdown – Indicates the engine is running at an unsafe speed. This is considered a major fault.

F.Engine Running – Indicates that engine is running at a safe operating speed.

Located behind the generator control panel is the Generator Control Box. This box contains some of the necessary electronic components required to make the generator function.

The Control Box is equipped with the following major components:

Over-Current Relay

Voltage Rectifer (AVR)

Starter Relay

Current Transformer

Voltage Selector Switch

Three Phase Circuit Breaker

Remember the overcurrent

NOTErelay monitors the current flowing from the U,V, and W Output Terminal Lugs to the load.

In the event of a short circuit or over current condition, it will automatically trip the 600 amp main breaker.

To restore power to the Output Terminal Panel, press the reset button on the overcurrent relay and place the main circuit breaker in the closed position (ON).

DCA-400SSV— OPERATION AND PARTS MANUAL — REV. #0 (04/19/06) — PAGE 21

Page 21
Image 21
Multiquip operation manual DCA-400SSV- Generator Control Panel

DCA-400SSV specifications

The Multiquip DCA-400SSV is a versatile and reliable mobile generator designed to meet the demanding energy needs of various applications, from construction sites to outdoor events. With a robust combination of power output, efficiency, and portability, this generator stands out in the market for its performance capabilities.

At the heart of the DCA-400SSV is its powerful diesel engine, which delivers a remarkable output of up to 400 kVA. This makes it suitable for large-scale operations, ensuring that equipment runs smoothly and efficiently without interruptions. The generator is equipped with a state-of-the-art soundproof enclosure, significantly reducing noise levels and allowing for unobtrusive operation in areas where noise regulations are strict.

One of the main features of the DCA-400SSV is its advanced digital control system. This technology provides real-time monitoring and control of generator performance, allowing users to track vital parameters such as voltage, frequency, and operational hours. This capability ensures optimized performance, contributing to prolonged lifespan and reduced maintenance costs. Moreover, the control panel is designed for user-friendliness, making it easy for operators to adjust settings and monitor performance at a glance.

Fuel efficiency is another critical characteristic of the DCA-400SSV. The generator is engineered to minimize fuel consumption while maximizing power output. This feature is particularly beneficial in projects where fuel costs can quickly add up, making the DCA-400SSV an economical choice for long-term operations.

The mobility of the DCA-400SSV is enhanced by its compact design and equipped wheels. This facilitates easy transportation between job sites. Additionally, its rugged construction ensures it can withstand tough environments, making it ideal for industrial and construction applications where reliability is paramount.

Safety features, such as auto shutdown mechanisms for low oil pressure and high temperature, further enhance the dependability of the DCA-400SSV. These safety protocols protect both the generator and the equipment it powers, reducing the likelihood of operational failures.

In summary, the Multiquip DCA-400SSV is a powerful and efficient mobile generator that excels in providing reliable energy solutions across various environments. Its blend of advanced technology, safety features, and practicality makes it a popular choice among contractors and event organizers alike. With its exceptional performance, the DCA-400SSV is designed to meet the challenges of demanding jobs while ensuring user convenience and satisfaction.