Multiquip DCA-400SSV- Maintenance, General Inspection Air Cleaner, Air filter should not be

Models: DCA-400SSV

1 98
Download 98 pages 20.12 Kb
Page 40
Image 40

DCA-400SSV— MAINTENANCE

TABLE 14. INSPECTION/MAINTENANCE

 

10 Hrs

250 Hrs

500 Hrs

 

1000 Hrs

 

DAILY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check Engine Fluid Levels

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

Check Air Cleaner

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

Check Battery Acid Level

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

Check Fan Belt Condition

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

Check for Leaks

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

Check for Loosening of Parts

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace Engine Oil and Filter * 1

 

 

X

 

 

 

 

 

 

 

 

 

 

 

ENGINE

Clean Air Filter

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

Check Fuel Filter/Water Seperator Bowl

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

Clean Unit, Inside and Outside

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

Change Fuel Filter

 

 

 

X

 

 

 

 

 

 

 

 

 

 

 

Clean Radiator and Check Coolant Protection Level*2

 

 

 

X

 

 

 

 

 

 

 

 

 

 

 

Replace Air Filter Element * 3

 

 

 

X

 

 

 

Check all Hoses and Clamps * 4

 

 

 

 

 

X

 

Clean Inside of Fuel Tank

 

 

 

 

 

X

 

 

 

 

 

 

 

 

GENERATOR

Measure Insulation Resistance Over 3M ohms

 

 

X

 

 

 

 

 

 

 

 

 

 

 

Check Rotor Rear Support Bearing

 

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*1

Replace engine oil anf filter at 100 hours, first time only.

 

 

 

 

 

*2

Add "Supplemental Coolant Addatives (SCA'S)" to recharge the engine coolant.

 

 

 

 

*3 Replace primary air filter element when restriction indicator shows a vaccum of 625 mm (25 in. H20).

 

 

*4

If blowby hose needs to be replaced, ensure that the slope of the bloby hose is at least a 1/2 inch per foot, with

 

 

no sags or dips that could collect moisture and/or oil.

 

 

 

 

 

General Inspection

Prior to each use, the generator should be cleaned and inspected for deficiencies. Check for loose, missing or damaged nuts, bolts or other fasteners. Also check for fuel, oil, and coolant leaks.Use Table 14 as a general maintenance guideline Engine Side (Refer to the Engine Instruction Manual)

Air Cleaner

Every 250 hours: Remove air cleaner element (Figure 59) and clean the heavy duty paper element with light spray of compressed air. Replace the air cleaner as needed.

Air Cleaner with Dust Indicator

This indicator (Figure 58) is attached to the air cleaner.When the air cleaner element is clogged, air intake restriction becomes greater and the dust indicator signal shows RED meaning the element needs changing or service. After changing the air element, press the dust indicator button to reset the indicator.

Figure 58. Air Cleaner/Indicator

The air filter should not be

NOTE changed until the indicator reads “RED”. Dispose of old air filter it may not be cleaned or reused.

PAGE 40 — DCA-400SSV— OPERATION AND PARTS MANUAL — REV. #0 (04/19/06)

Page 40
Image 40
Multiquip operation manual DCA-400SSV- Maintenance, General Inspection Air Cleaner, Air Cleaner with Dust Indicator