Battery

This unit is of negative ground. DO NOT connect in reverse. Always maintain battery fluid level between the specified marks. Battery life will be shortened, if the fluid level is not properly maintained. Add only distilled water when replenishment is necessary. DO NOT over fill.

The battery is sufficiently charged if the specific gravity of the battery fluid is 1.28 (at 68° F). If the specific gravity should fall to 1.245 or lower, it indicates that the battery is dead and needs to be recharged or replaced.

Check to see whether the battery cables are loose. Poor contact may result in poor starting or malfunctions. Always keep the terminals firmly tightened. Coating the terminals with a thin film of grease will help to inhibit corrosion.

Battery Cable Installation

ALWAYS be sure the battery cables (Figure 35) are properly connected to the battery terminals as shown below.The RED cable is connected to the positive terminal of the battery, and the BLACK cable is connected to the negative terminal of the battery.

Figure 35. Battery Connections

Alternator

The polarity of the alternator is negative grounding type. When an inverted circuit connection takes place, the circuit will be in short circuit instantaneously resulting the alternator failure.

Do not put water directly on the alternator. Entry of water into the alternator leads an electrolyte corrosion causing an alternator failure.

Before charging the battery with an external electric source, be sure to disconnect the battery cables.

DCA-60SSAIPRE-SETUP

CAUTION :

If the battery cable is connected incorrectly, damage to the generator will occur. Pay close attention to the polarity of the battery when connecting the battery.

When connecting battery do the following:

1.DO NOT connect the battery cables to the battery terminals when the key is in the ignition and is set in 'START' mode. ALWAYS remove the key from the ignition and the ignition switch is in the OFF position when connecting the battery.

2.Place a small amount of grease around both battery terminals. This will ensure a good connection and will help prevent corrosion around the battery terminals.

CAUTION :

Inadequate battery connections may cause poor starting of the generator, and create other malfunctions.

Wiring

Inspect the entire generator for bad or worn electrical wiring or connections. If any wiring or connections are exposed (insulation missing) replace wiring immediately.

Piping and Hose Connection

Inspect all piping, oil hose, and fuel hose connections for wear and tightness.Tighten all hose clamps and check hoses for leaks.

If any hose (fuel or oil) lines are defective replace them immediately.

DCA-60SSAI — PARTS AND OPERATION MANUAL— FINAL COPY (09/15/01) — PAGE 45

Page 45
Image 45
Multiquip dca-60ssai DCA-60SSAI PRE-SETUP, Battery Cable Installation, Alternator, Wiring, Piping and Hose Connection

dca-60ssai specifications

The Multiquip DCA-60SSAI is a portable diesel generator that stands out in the world of reliable power solutions, designed for a range of applications including construction, events, and emergency backup. With its robust build and advanced features, the DCA-60SSAI has earned a reputation for durability and efficiency.

One of the primary features of the DCA-60SSAI is its powerful 60 kVA output capacity. This generator is equipped with a high-performance, water-cooled, four-stroke diesel engine, providing not only ample power but also long-lasting operation. The unit ensures reliable performance under demanding conditions, making it suitable for heavy-duty applications.

In terms of technologies, the DCA-60SSAI incorporates a state-of-the-art digital control panel. This user-friendly interface enables operators to easily monitor voltage, frequency, and operating hours, which enhances the generator's manageability. The built-in automatic voltage regulator (AVR) maintains consistent voltage output, ensuring sensitive electronic equipment can operate safely and efficiently.

Moreover, the generator features a sound-attenuated enclosure that significantly reduces noise levels, making it more suitable for urban environments and noise-sensitive applications. This design does not only provide peace and quiet but also protects the internal components from the elements, extending the life of the generator.

When it comes to fuel efficiency, the DCA-60SSAI is optimized to consume less diesel compared to traditional generators of similar capacity. This fuel efficiency not only reduces operational costs but also decreases the frequency of refueling, which is a significant advantage for long-term projects or remote worksites.

Additionally, the DCA-60SSAI is equipped with multiple output options. This versatility makes it ideal for various applications, whether powering construction equipment, lighting, or other essential machinery on-site. Safety features like low oil pressure shutdown and emergency stop buttons ensure that the generator operates safely and that operators are protected.

In summary, the Multiquip DCA-60SSAI is a powerful, efficient, and versatile diesel generator designed to meet the demands of industrial and commercial applications. With its durability, advanced features, and user-friendly technologies, it provides reliable power solutions that users can depend on in any situation.