RULES FOR SAFE OPERATION

Battery

CAUTION:

Never over fill the battery with water above the upper limit.

The battery contains acids that can cause injury to the eyes and skin.To avoid eye irritation, always wear safety glasses. Use well insulated gloves when picking up the battery. Use the following guidelines when handling the battery:

1.DO NOT drop the battery. There is the possibility of risk that the battery may explode.

2.DO NOT expose the battery to open flames, sparks, cigarettes etc. The battery contains combustible gases and liquids. If these gases and liquids come in contact with a flame or spark, an explosion could occur.

3.Always keep the battery charged. If the battery is not charged a buildup of combustible gas will occur.

4.Always keep battery charging and booster cables in good working condition. Repair or replace all worn cables.

5.Always recharge the battery in an open air environment, to avoid risk of a dangerous concentration of combustible gases.

6.In case the battery liquid (dilute sulfuric acid) comes in contact with clothing or skin, rinse skin or clothing immediately with plenty of water.

7.In case the battery liquid (dilute sulfuric acid) comes in contact with your eyes, rinse eyes immediately with plenty of water, then contact the nearest doctor or hospital, and seek medical attention.

NEVER Run engine without air filter. Severe engine damage may occur.

Always service air cleaner frequently to prevent carburetor malfunction.

Always disconnect the battery before performing service on the generator.

Always be sure the operator is familiar with proper safety precaution s and operations techniques before using generator.

Always store equipment properly when not in use. Equipment should be stored in a clean, dry location out of the reach of children.

DO NOT leave the generator running in the manual mode unattended.

DO NOT allow unauthorized people to operate this equipment.

Always read, understand, and follow procedures in Operator’s Manual before attempting to operate equipment.

Refer to the Isuzu Engine Owner's Manual for engine technical questions or information.

Loading and Unloading (Crane)

Before lifting, make sure the generator's lifting hook is secure and that there is no apparent damage to the generator itself (loose screws, nuts and bolts). If any part is loose or damaged, please take corrective action before lifting.

Always drain fuel prior to lifting.

Always make sure crane or lifting device has been properly secured to the hook of guard frame on generator.

NEVER lift the machine while the engine is running.

Use adequate lifting cable (wire or rope) of sufficient strength.

When lifting the generator, always use the balanced center-point suspension hook and lift straight upwards.

NEVER allow any person or animal to stand underneath the machine while lifting.

When loading the generator on a truck, be sure to use the front and back frame bars as a means to secure the generator during transport.

PAGE 8 — DCA-60SSAI — PARTS AND OPERATION MANUAL— FINAL COPY (09/15/01)

Page 8
Image 8
Multiquip dca-60ssai operation manual Battery, Loading and Unloading Crane

dca-60ssai specifications

The Multiquip DCA-60SSAI is a portable diesel generator that stands out in the world of reliable power solutions, designed for a range of applications including construction, events, and emergency backup. With its robust build and advanced features, the DCA-60SSAI has earned a reputation for durability and efficiency.

One of the primary features of the DCA-60SSAI is its powerful 60 kVA output capacity. This generator is equipped with a high-performance, water-cooled, four-stroke diesel engine, providing not only ample power but also long-lasting operation. The unit ensures reliable performance under demanding conditions, making it suitable for heavy-duty applications.

In terms of technologies, the DCA-60SSAI incorporates a state-of-the-art digital control panel. This user-friendly interface enables operators to easily monitor voltage, frequency, and operating hours, which enhances the generator's manageability. The built-in automatic voltage regulator (AVR) maintains consistent voltage output, ensuring sensitive electronic equipment can operate safely and efficiently.

Moreover, the generator features a sound-attenuated enclosure that significantly reduces noise levels, making it more suitable for urban environments and noise-sensitive applications. This design does not only provide peace and quiet but also protects the internal components from the elements, extending the life of the generator.

When it comes to fuel efficiency, the DCA-60SSAI is optimized to consume less diesel compared to traditional generators of similar capacity. This fuel efficiency not only reduces operational costs but also decreases the frequency of refueling, which is a significant advantage for long-term projects or remote worksites.

Additionally, the DCA-60SSAI is equipped with multiple output options. This versatility makes it ideal for various applications, whether powering construction equipment, lighting, or other essential machinery on-site. Safety features like low oil pressure shutdown and emergency stop buttons ensure that the generator operates safely and that operators are protected.

In summary, the Multiquip DCA-60SSAI is a powerful, efficient, and versatile diesel generator designed to meet the demands of industrial and commercial applications. With its durability, advanced features, and user-friendly technologies, it provides reliable power solutions that users can depend on in any situation.