Valve Clearance Check

1.In order to bring No. 1 or No. 4 cylinder to top dead center in the compression stroke, align the notched line on the crank pulley with TDC mark on the timing gear case cover.

2.Do the adjustment on the circle marked valves in the below table where No. 1 cylinder is at the center in the compression stroke.

3.After adjustment started from either piston top center, turn the crankshaft 360o to align the notched line with the TDC mark to do the adjustment again on the remaining valve. See Table 16 and Figure 55 for valve arrangement.

Injection Timing Check and Adjustment

1.Bring No. cylinder to the top dead center on the compression stroke.

2.Turn the crankshaft pulley clockwise (viewed at engine front) and align the notched line on the crank pulley with the TDC mark on the timing gear case cover.

Figure 58. Valve Adjustment

NOTE:

Take necessary precautions to prevent dust and foreign particles in the pump interior when timing adjustments are made.

3.Remove the timing check hole cover at the front of injection pump to check the alignment between the pointer “a” on the injection pump gear lock plate and the projected area mark “b” on the timing gear case.

4.If “a” and “b” are in alignment, the timing is set correctly. If not, follow nos. 1-3 until the “a” and “b” are aligned.

5.Reversely turn the crankshaft pulley counterclockwise viewed at the engine front about 30o crank angle.

6.Remove No. 1 injection pipe from the engine.

7.Remove the injection pump No. 1 delivery valve holder, delivery valve and spring and reinstall the delivery valve holder on the original place.

8.Delivery valve holder tightening torque: 39~44Nm(29~33lbft.)

9.Slowly turn the crankshaft pulley clockwise and at the same time continue to feed the fuel with pumping the Feed pump. When the fuel stop to flow out from No. 1 delivery valve holder, stop pumping.

10.Observe and make sure which mark (injection starting angle line) on the timing gear case cover is aligning with the notched line on the crank pulley.

11.The timing line shows the injection starting crank angle of the engine.

12.The injection starting crank angle should be at the 14o timing mark.

Table 15. Valve Adustment

(I=Inlet; E=Exhaust)

Cylinder No.

 

1

 

2

 

3

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

Valve Arrangement

I

 

E

I

 

E

I

 

E

I

 

E

 

 

 

 

 

 

 

 

 

 

 

 

 

When No. 1 is at top

X

 

X

X

 

 

 

 

X

 

 

 

dead center in the

 

 

 

 

 

 

 

 

 

 

 

 

compression stoke

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

When No. 4 is at top

 

 

 

 

 

O

O

 

 

O

 

O

dead center in the

 

 

 

 

 

 

 

 

 

 

 

 

compression stroke

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PAGE 54 — DCA-60SSAI — PARTS AND OPERATION MANUAL— FINAL COPY (09/15/01)

Page 54
Image 54
Multiquip dca-60ssai operation manual Valve Clearance Check, Injection Timing Check and Adjustment

dca-60ssai specifications

The Multiquip DCA-60SSAI is a portable diesel generator that stands out in the world of reliable power solutions, designed for a range of applications including construction, events, and emergency backup. With its robust build and advanced features, the DCA-60SSAI has earned a reputation for durability and efficiency.

One of the primary features of the DCA-60SSAI is its powerful 60 kVA output capacity. This generator is equipped with a high-performance, water-cooled, four-stroke diesel engine, providing not only ample power but also long-lasting operation. The unit ensures reliable performance under demanding conditions, making it suitable for heavy-duty applications.

In terms of technologies, the DCA-60SSAI incorporates a state-of-the-art digital control panel. This user-friendly interface enables operators to easily monitor voltage, frequency, and operating hours, which enhances the generator's manageability. The built-in automatic voltage regulator (AVR) maintains consistent voltage output, ensuring sensitive electronic equipment can operate safely and efficiently.

Moreover, the generator features a sound-attenuated enclosure that significantly reduces noise levels, making it more suitable for urban environments and noise-sensitive applications. This design does not only provide peace and quiet but also protects the internal components from the elements, extending the life of the generator.

When it comes to fuel efficiency, the DCA-60SSAI is optimized to consume less diesel compared to traditional generators of similar capacity. This fuel efficiency not only reduces operational costs but also decreases the frequency of refueling, which is a significant advantage for long-term projects or remote worksites.

Additionally, the DCA-60SSAI is equipped with multiple output options. This versatility makes it ideal for various applications, whether powering construction equipment, lighting, or other essential machinery on-site. Safety features like low oil pressure shutdown and emergency stop buttons ensure that the generator operates safely and that operators are protected.

In summary, the Multiquip DCA-60SSAI is a powerful, efficient, and versatile diesel generator designed to meet the demands of industrial and commercial applications. With its durability, advanced features, and user-friendly technologies, it provides reliable power solutions that users can depend on in any situation.