Multiquip DCA125SSIU Outdoor Installation, Indoor Installation, Mounting, Generator Grounding

Models: DCA125SSIU

1 90
Download 90 pages 9.4 Kb
Page 15
Image 15

INSTALLATION

OUTDOOR INSTALLATION

Install the generator in a area that is free of debris, bystanders, and overhead obstructions. Make sure the generator is on secure level ground so that it cannot slide or shift around. Also install the generator in a manner so that the exhaust will not be discharged in the direction of nearby homes.

The installation site must be relatively free from moisture and dust. All electrical equipment should be protected from excessive moisture. Failure to do will result in deterioration of the insulation and will result in short circuits and grounding.

Foreign materials such as dust, sand, lint and abrasive materials have a tendency to cause excessive wear to engine and alternator parts.

CAUTION

Pay close attention to ventilation when operating the generator inside tunnels and caves.The engine exhaust contains noxious elements. Engine exhaust must be routed to a ventilated area.

INDOOR INSTALLATION

Exhaust gases from diesel engines are extremely poisonous. Whenever an engine is installed indoors the exhaust fumes must be vented to the outside. The engine should be installed at least two feet from any outside wall. Using an exhaust pipe which is too long or too small can cause excessive back pressure which will cause the engine to heat excessively and possibly burn the valves.

MOUNTING

The generator must be mounted on a solid foundation (such as concrete) and set fi rmly on the foundation to isolate vibration of the generator when it is running.The generator must set at least 6 inches above the fl oor or grade level (in accordance to NFPA 110, Chapter 5-4.1). DO NOT remove the metal skids on the bottom of the generator. They are to resist damage to the bottom of the generator and to maintain alignment.

GENERATOR GROUNDING

To guard against electrical shock and possible damage to the equipment, it is important to provide a good EARTH ground.

Article 250 (Grounding) of the National Electrical Code (NEC) provides guide lines for proper grounding and specifi es that the cable ground shall be connected to the grounding system of the building as close to the point of cable entry as practical.

NEC articles 250-64(b) and 250-66 set the following grounding requirements:

1.Use one of the following wire types to connect the generator to earth ground.

a.Copper - 8 AWG (5.3 mm2)

b.Aluminum - 6 AWG (8.4 mm2)

2.When grounding the generator (Figure 2) connect the ground cable between the lock washer and the nut on the generator and tighten the nut fully. Connect the other end of the ground cable to earth ground.

3.NEC article 250-52(c) specifies that the earth ground rod should be buried a minimum of 8 ft. into the ground.

NOTICE

When connecting the generator to any buildings electrical system ALWAYS consult with a licensed electrician.

DCA125SSIU 60 HZ GENERATOR • OPERATION AND PARTS MANUAL — REV. #3 (01/13/11) — PAGE 15

Page 15
Image 15
Multiquip DCA125SSIU manual Outdoor Installation, Indoor Installation, Mounting, Generator Grounding

DCA125SSIU specifications

The Multiquip DCA125SSIU is a robust and versatile diesel generator that is designed to meet the power needs of various applications, from construction sites to events and emergency situations. With a power output of 125 kVA, this generator combines efficiency and reliability, making it an ideal choice for professionals who demand optimal performance in challenging environments.

One of the primary features of the DCA125SSIU is its industrial-grade a diesel engine. This engine not only delivers impressive power but also emphasizes fuel efficiency. The generator is equipped with advanced fuel management technologies that help minimize consumption while maximizing output, making it cost-effective for long-term use.

In terms of durability, the DCA125SSIU is built with a sturdy enclosure that protects it from environmental factors. The weather-resistant design ensures that it operates effectively in a variety of weather conditions, ensuring reliable performance when needed the most. Additionally, its compact size allows for easy transport and storage, which is particularly beneficial for contractors and rental companies.

The DCA125SSIU features a user-friendly control panel that provides essential information at a glance. This panel includes gauges for monitoring key parameters such as voltage, frequency, and hours of operation. It also has an automatic voltage regulator (AVR) that maintains consistent voltage output, safeguarding connected equipment from potential damage caused by power fluctuations.

Safety is a priority with the DCA125SSIU, as it is equipped with several emergency shutdown features. These include low oil pressure, high temperature, and overload protection, ensuring that the generator operates safely under all conditions. Further enhancing its operational reliability, the generator comes with a built-in fuel tank that allows for extended runtime, reducing the frequency of refueling during use.

In summary, the Multiquip DCA125SSIU is a powerful, durable, and efficient diesel generator that meets the diverse power needs of various industries. Its combination of a high-performance engine, user-friendly control panel, robust safety features, and fuel efficiency makes it an exceptional choice for anyone looking for a reliable power solution. Whether for temporary power during events, backup for critical systems, or support at construction sites, the DCA125SSIU is engineered to perform.