SAFETY INFORMATION

FUEL SAFETY

DANGER

DO NOT start the engine near spilled fuel or combustible fl uids. Diesel fuel is extremely fl ammable and its vapors can cause an explosion if ignited.

ALWAYS refuel in a well-ventilated area, away from sparks and open fl ames.

ALWAYS use extreme caution when working with flammable liquids.

DO NOT fi ll the fuel tank while the engine is running or hot.

DO NOT overfi ll tank, since spilled fuel could ignite if it comes into contact with hot engine parts or sparks from the ignition system.

Store fuel in appropriate containers, in well-ventilated areas and away from sparks and fl ames.

NEVER use fuel as a cleaning agent.

DO NOT smoke around or near the equipment. Fire or explosion could result

from fuel vapors or if fuel is spilled on a hot engine.

TOWING SAFETY

CAUTION

Check with your local county or state safety

towing regulations, in addition to meeting

Department of Transportation (DOT) SafetyTowing Regulations, before towing your generator.

Refer to MQ Power trailer manual for additional safety information.

In order to reduce the possibility of an accident while transporting the generator on public roads, ALWAYS make sure the trailer that supports the generator and the towing vehicle are mechanically sound and in good operating condition.

ALWAYS shutdown engine before transporting

Make sure the hitch and coupling of the towing vehicle are rated equal to, or greater than the trailer “gross vehicle weight rating.”

ALWAYS inspect the hitch and coupling for wear. NEVER tow a trailer with defective hitches, couplings, chains, etc.

Check the tire air pressure on both towing vehicle and trailer. Trailer tires should be inflated to 50 psi cold. Also check the tire tread wear on both vehicles.

ALWAYS make sure the trailer is equipped with a safety chain.

ALWAYS properly attach trailer’s safety chains to towing vehicle.

ALWAYS make sure the vehicle and trailer directional, backup, brake and trailer lights are connected and working properly.

DOT Requirements include the following:

Connect and test electric brake operation.

Secure portable power cables in cable tray with tie wraps.

The maximum speed for highway towing is 55 MPH unless posted otherwise. Recommended off-road towing is not to exceed 15 MPH or less depending on type of terrain.

Avoid sudden stops and starts.This can cause skidding, or jack-knifi ng. Smooth, gradual starts and stops will improve towing.

Avoid sharp turns to prevent rolling.

Trailer should be adjusted to a level position at all times when towing.

Raise and lock trailer wheel stand in up position when towing.

Place chock blocks underneath wheel to prevent rolling while parked.

Place support blocks underneath the trailer’s bumper to prevent tipping while parked.

Use the trailer’s swivel jack to adjust the trailer height to a level position while parked.

DCA125SSIU 60 HZ GENERATOR • OPERATION AND PARTS MANUAL — REV. #3 (01/13/11) — PAGE 9

Page 9
Image 9
Multiquip DCA125SSIU manual Fuel Safety, Towing Safety,  Never use fuel as a cleaning agent

DCA125SSIU specifications

The Multiquip DCA125SSIU is a robust and versatile diesel generator that is designed to meet the power needs of various applications, from construction sites to events and emergency situations. With a power output of 125 kVA, this generator combines efficiency and reliability, making it an ideal choice for professionals who demand optimal performance in challenging environments.

One of the primary features of the DCA125SSIU is its industrial-grade a diesel engine. This engine not only delivers impressive power but also emphasizes fuel efficiency. The generator is equipped with advanced fuel management technologies that help minimize consumption while maximizing output, making it cost-effective for long-term use.

In terms of durability, the DCA125SSIU is built with a sturdy enclosure that protects it from environmental factors. The weather-resistant design ensures that it operates effectively in a variety of weather conditions, ensuring reliable performance when needed the most. Additionally, its compact size allows for easy transport and storage, which is particularly beneficial for contractors and rental companies.

The DCA125SSIU features a user-friendly control panel that provides essential information at a glance. This panel includes gauges for monitoring key parameters such as voltage, frequency, and hours of operation. It also has an automatic voltage regulator (AVR) that maintains consistent voltage output, safeguarding connected equipment from potential damage caused by power fluctuations.

Safety is a priority with the DCA125SSIU, as it is equipped with several emergency shutdown features. These include low oil pressure, high temperature, and overload protection, ensuring that the generator operates safely under all conditions. Further enhancing its operational reliability, the generator comes with a built-in fuel tank that allows for extended runtime, reducing the frequency of refueling during use.

In summary, the Multiquip DCA125SSIU is a powerful, durable, and efficient diesel generator that meets the diverse power needs of various industries. Its combination of a high-performance engine, user-friendly control panel, robust safety features, and fuel efficiency makes it an exceptional choice for anyone looking for a reliable power solution. Whether for temporary power during events, backup for critical systems, or support at construction sites, the DCA125SSIU is engineered to perform.