Multiquip HTN-27K-TCSL Make sure the correct depth air, Air Cleaner Components to Check

Models: HTN-27K-TCSL

1 46
Download 46 pages 4.37 Kb
Page 27
Image 27

Air Cleaner Components - See Figure 13.

1. Air Cleaner Cover

2. Latch Spring

3.Lever Latch

4. Latch Lever Pin

5. Wing Nut

6. Inner Air Cleaner Cover

7.Precleaner Element

8.Air Cleaner Element

9. seal

10. Air Cleaner Bracket

11.Air Cleaner Base

12.Air Cleaner Base Gasket

13.Intake Manifold Gasket

14.Intake Manifold

15.screw

Paper Element Service (StandardType)

Check the paper element every 100 hours of operation (more often under extremely dusty or dirty conditions). Replace the element as necessary.

Refer to the following steps and to Figure 13:

1.Release the latches located on either side of the air cleaner cover (Figure 13), and remove the cover.

2.Remove the wing nut, element cover, seal and air cleaner element.

3.Remove the precleaner (if so equipped) from the paper element.

4.Do not wash the paper element or use pressurized air, as this will damage the element. Replace a dirty, bent, or damaged element with a new element as prescribed by the engine manufacturer. Handle new elements carefully; do not use if the sealing surfaces are bent or damaged.

5.Reinstall the seal, paper element, precleaner, element cover, flat washer and wing nut.

6.Reinstall the air cleaner cover and secure the latches.

Make sure the correct depth air

NOTE cleaner element and rubber seal are used for the engine spec. involved.

HTN-SERIES — MAINTENANCE

Air Cleaner - Components to Check

Whenever the air cleaner cover is removed, or the paper element or precleaner is serviced, check the following:

Air Cleaner Element Cover and Seal - Make sure the element cover is not bent or damaged. Make sure the wing nut, washer and seal are in place to ensure the element is sealed against leakage.

Air Cleaner Base - Make sure the base is secured tightly to carburetor and not cracked or damaged.

BreatherTube - Make sure the tube is installed to both the air cleaner base and the breather cover.

Disassembly and Reassembly (Standard Type)

If the base plate on the standard type must be removed, proceed as follows:

1.Remove the air cleaner components as described previously.

2.Remove the hex flange screws securing the bracket and base.

3.Remove the base and gasket. Carefully pull the rubber breather tube through the base

4.Remove the tube from under side of base if necessary.

5.Reverse the foregoing steps to reinstall new or service components.Tighten screw to 9.9 N-m (88 in. lb.) torque.

Air Intake/Cooling System

To ensure proper cooling, make sure the grass screen and fan cooling fins and other external surfaces of the engine are kept clean at all times.

Every 100 hours of operation (more often under extremely dusty or dirty conditions:

1.Remove the blower housing and other cooling shrouds.

2.Clean the cooling fins and external surfaces as necessary.

3.Make sure the cooling shrouds are reinstalled.

CAUTION

Operating the engine with a blocked grass screen, dirty or plugged cooling fins, and/or cooling shrouds removed, will cause engine damage due to overheating.

HTN- SERIES • RIDE-ON POWER TROWEL — OPERATION MANUAL — REV. #0 (06/06/07) — PAGE 27

Page 27
Image 27
Multiquip HTN-27K-TCSL Make sure the correct depth air, Air Cleaner Components to Check, Air Intake/Cooling System

HTN-27K-TCSL specifications

The Multiquip HTN-27K-TCSL is a cutting-edge piece of technology designed for professionals in the construction and industrial sectors. This portable hydraulic power unit is known for its robust performance and versatility, making it an ideal choice for a wide range of applications.

One of the standout features of the HTN-27K-TCSL is its powerful engine. Equipped with a reliable 27-horsepower Kohler engine, this unit ensures maximum efficiency and performance, allowing operators to complete tasks quickly and effectively. The engine is designed to be both fuel-efficient and environmentally friendly, adhering to emission regulations without sacrificing power.

The HTN-27K-TCSL boasts a unique hydraulic system that delivers high-pressure flow rates, making it suitable for operating multiple tools simultaneously. With a maximum hydraulic pressure of 3,000 PSI, this power unit can effortlessly handle demanding tasks such as concrete breaking, water jetting, and other heavy-duty applications. The ability to provide consistent hydraulic power allows for enhanced productivity on job sites.

In terms of versatility, the Multiquip HTN-27K-TCSL is equipped with a wide range of output options. Its hydraulic outlet configurations can support various attachments, enabling users to adapt the unit for diverse tasks. This flexibility makes it an invaluable tool for contractors, landscapers, and utility companies.

Another notable characteristic of the HTN-27K-TCSL is its rugged construction. Built to withstand the rigors of tough job sites, this hydraulic power unit features a durable frame and protective covers that shield the engine and components from dust and debris. The compact design ensures easy transportation and maneuverability, making it a practical choice for both indoor and outdoor use.

Additionally, the HTN-27K-TCSL is designed with operator safety in mind. It features a user-friendly interface, with clearly labeled controls for easy operation. Safety features such as emergency shut-off switches and protective guards further enhance its usability, ensuring that operators can work confidently.

In summary, the Multiquip HTN-27K-TCSL is a powerful, versatile, and robust hydraulic power unit designed to meet the demanding needs of various industries. With its exceptional performance, durable construction, and focus on safety, it continues to be a trusted choice among professionals seeking reliable hydraulic solutions.