CONNECTINGTHE POWER

JIMMY SERIES HYDRAULIC REBAR BENDERS — APPLYING POWER

CONNECTINGTHE POWER

1.The electric-hydraulic pump requires 115 VAC, 60 Hz power. Applying power to the pump that is not speci- fied will cause severe damage to the pump's electric motor. Always read the electrical data plate before applying power to the pump.

2.The power plug on the pump is a 3-prong grounded type plug. ALWAYS connect this plug to a 3-prong grounded receptacle. NEVER plug this device into a 2-prong type receptacle.This will defeat the ground circuit.The use of a 3-prong to 2-prong adapter is strictly prohibited.

3.Connect the pump's AC power cord to a 115 VAC wall receptacle or portable generator (Figure 7) that is pro- tected by a 20 amp circuit breaker. For best results connect the power cord to a GFCI receptacle.

Since distance can affect voltage drop when using an extension cord,

NOTE ALWAYS make certain that the proper extension cord has been se- lected for the job. See Table 4.

4.Connectthehand-heldremotecontrolcabletothe power input receptacle on the power unit

5.To apply power to the electric-hydraulic pump, place the ON/OFF toggle switch (Figure 7) to the ON position (up).

Figure 7. Connecting The Power

DANGER - ELECTROCUTION HAZARDS

During operation of this rebar bender, there exists the possibility of electrocution, electrical shock or burn, which can cause severe bodily harm or even DEATH!

To avoid these hazards:

NEVER use damaged or worn cables when plugging the rebar bender into an AC power receptacle.

Table 4. Cable Selection (60 Hz, Single Phase Operation)

 

Load In

 

Maximum Allowable Cable Length

 

Current in

Watts

 

 

 

 

 

 

 

 

 

 

 

 

 

Amperes

At 120

#10 Wire

#12 Wire

#14 Wire

#16 Wire

 

 

Volts

 

 

 

 

 

 

 

 

 

 

 

 

 

2.5

300

1000 ft.

600

ft.

375 ft.

250 ft.

 

 

 

 

 

 

 

5

600

500 ft.

300

ft.

200 ft.

125 ft.

 

 

 

 

 

 

 

7.5

900

350 ft.

200

ft.

125 ft.

100 ft.

NEVER grab or touch a live power cord with wet hands.

NEVER stand in water and touch a live power cord.

WET

HANDS

POWER

CORD

(POWER ON)

10

1200

250 ft.

150

ft.

100 ft.

 

 

 

 

 

 

 

 

15

1800

150

ft.

100

ft.

65

ft.

 

 

 

 

 

 

 

20

2400

125

ft.

75 ft.

50

ft.

 

 

 

CAUTION: Equipment damage can result from low voltage.

 

 

JIMMY SERIES HYDRAULIC REBAR BENDERS — OPERATION AND PARTS MANUAL — REV. #9 (01/04/08) — PAGE 15