inspection

Coolant

It is recommended that antifreeze/summer coolant be used with the engine. This can be purchased pre-diluted or in concentrate and mixed with 50% demineralized water. See engine owner's manual for more details.

WARNING

If adding coolant/antifreeze mix to the radiator, DO NOT remove the radiator cap until the unit has completely cooled. The possibility of hot coolant exists which can

cause severe burns.

Day-to-day addition of coolant is done from the recovery tank.When adding coolant to the radiator, DO NOT remove the radiator cap until the unit has completely cooled. See Table 5 for engine and radiator, coolant capacities. Make sure the coolant level in the recovery tank is always between the "H" and the "L" markings.

Table 5. Coolant Capacity

Engine Type

Coolant Capacity

Perkins 103-10

5 qt. (4.7 liters)

Lombardini LDW 1003

5.18 qt. (4.9 liters)

Deutz F3M1008F

5.18 qt. (4.9 liters)

Operation in Freezing Weather

When operating in freezing weather, make sure the proper amount of antifreeze (Table 6) has been added.

Table 6. Anti-Freeze Operating Temperatures

Vol (%)

Freezing Point

Boiling Point

 

 

 

 

Anti-Freeze

°C

°F

°C

°F

 

 

 

 

 

40

-24

-12

106

222

 

 

 

 

 

50

-37

-34

108

226

 

 

 

 

 

NOTICE

When the antifreeze is mixed with water, the antifreeze mixing ratio must be less than 50%.

Cleaning the Radiator

The engine may overheat if the radiator fins become overloaded with dust or debris. Periodically clean the radiator fins with compressed air. Cleaning inside the machine is dangerous, so clean only with the engine turned off and the negative battery terminal disconnected.

Air Cleaner

Periodic cleaning/replacement of the air cleaner is necessary. Inspect it in accordance with the engine owner's manual.

Fan Belt Tension

A slack fan belt may contribute to overheating, or to insufficient charging of the battery. Inspect the fan belt for damage and wear and adjust it in accordance with the engine owner's manual.

The fan belt tension is proper if the fan belt bends 10 to 15 mm when depressed with the thumb as shown in Figure 9.

Figure 9. Fan Belt Tension

WARNING

Never place hands near the belts or fan while the engine is running.

WARNING

The engine's exhaust contains harmful emissions. ALWAYS ventilate the exhaust when operating inside tunnels, excavations or buildings. Direct exhaust away from nearby personnel.

Before starting the engine, make sure of the following:

„„The electrical load is disconnected and the main circuit breaker and all lamp (4) circuit breakers are switched to the OFF position.

page 22 — LT12Dab LIGHT TOWER • operation manual — rev. #0 (06/03/11)

Page 22
Image 22
Multiquip LT12DAB Coolant, Operation in Freezing Weather, Cleaning the Radiator, Air Cleaner Fan Belt Tension

LT12DAB specifications

The Multiquip LT12DAB is an innovative and reliable light tower designed to deliver efficient lighting solutions for various outdoor applications. Known for its robust construction and user-friendly features, the LT12DAB is ideal for construction sites, events, and emergency situations, providing flexibility and performance in a compact package.

One of the standout features of the LT12DAB is its powerful lighting system. It is equipped with four high-intensity LED lights, each delivering up to 12,000 lumens, ensuring ample illumination for expansive areas. The LED technology not only enhances visibility but also offers advantages in power consumption, resulting in reduced energy costs and longer operational life. The tower can be raised up to 30 feet, enabling it to cast a broad beam of light across large outdoor spaces.

The LT12DAB is built with advanced mobility in mind. It features a durable, weather-resistant frame that can withstand various environmental conditions, making it suitable for use in diverse locations. The all-terrain wheels provide enhanced maneuverability, allowing operators to transport the unit easily across job sites or uneven terrains. Additionally, the lightweight design ensures that it can be easily handled by a small crew.

Powering the LT12DAB is a reliable and fuel-efficient diesel generator that provides extended run times without frequent refueling. This generator not only supports the lighting system but can also power additional tools and equipment, adding versatility to its functionality. The unit is designed with low noise emissions, making it ideal for operation in noise-sensitive areas.

Ease of use is paramount in the design of the LT12DAB. The intuitive control panel allows users to operate the lights and generator effortlessly. The telescopic mast can be raised or lowered quickly, with safety features in place to prevent accidental collapse. Moreover, the integrated sensors monitor the oil levels and engine temperature, providing alerts for maintenance needs.

In summary, the Multiquip LT12DAB combines powerful lighting capabilities with robust construction and user-friendly features. Its mobility, energy efficiency, and reliability make it a valuable tool for any outdoor project, ensuring that worksites remain well-lit and safe, regardless of the conditions. Whether for construction, events, or emergencies, the LT12DAB stands out for its performance and adaptability, meeting the demands of today’s professional environments.