Coolant (ISUZU Antifreeze/Summer Coolant/Water)

ISUZU recommends ISUZU Antifreeze/Summer Coolant for use in thier engines, which can be purchased in concentrate (and mixed with 50% demineralized water) or pre-diluted. See the ISUZU Engine Owner's Manual for further details.

DCA-70SSIU (60 Hz) — PRE-SETUP

Cleaning the Radiator

The engine may overheat if the radiator fins become overloaded with dust or debris. Periodically clean the radiator fins with compressed air. Cleaning inside the machine is dangerous, so clean only with the engine turned off and the negative battery terminal disconnected.

WARNING - BURN HAZARDS

If adding coolant/antifreeze mix to the radiator, DO NOT remove the radiator cap until the unit has completely cooled.The possibility of hot! coolant exists which can cause severe burns.

Day-to-day addition of coolant is done from the recovery tank. When adding coolant to the radiator, DO NOT remove the radiator cap until the unit has completely cooled. See Table 12 for engine, radiator, and recovery tank coolant capacities. Make sure the coolant level in the recovery tank is always between the "H" and the "L" markings.

Air Cleaner

Periodic cleaning/replacement is necessary. Inspect it in accordance with the ISUZU Engine Owner's Manual.

Fan Belt Tension

A slack fan belt may contribute to overheating, or to insufficient charging of the battery. Inspect the fan belt for damage and wear and adjust it in accordance with the ISUZU

Engine Owner's Manual.

The fan belt tension is proper if the fan belt bends 10 to 15

mm(Figure 37) when depressed with the thumb as shown below.

Table 12. Coolant Capacity

Engine and Radiator

3.8 Gal. (14.4 liters)

 

 

Reserve Tank

2 Quarts (1.9 liters)

 

 

Operation FreezingWeather

When operating in freezing weather, be certain the proper amount of antifreeze (Table 13) has been added.

Table 13. Anti-Freeze

Operating Temperatures

Vol %

Freezing Point

 

 

Anti-Freeze

 

 

°C

°F

 

 

 

 

50

-37

-34

 

 

 

Figure 37. Fan Belt Tension

CAUTION - ROTATING PARTS

NEVER place hands near the belts or fan while the generator set is running.

NOTE

When the antifreeze is mixed with

water, the antifreeze mixing ratio

 

 

must be less than 50%.

PAGE 34 — DCA-70SSIU (60 Hz) — OPERATION AND PARTS MANUAL — REV. #1 (01/06/09)

Page 34
Image 34
Multiquip M2870300504 Cleaning the Radiator, Air Cleaner Fan Belt Tension, Operation FreezingWeather, Vol % Freezing Point