Multiquip MGX manual Shaft lubrication 200 Hours, Vibrator head wear 300 Hours

Models: MGX

1 30
Download 30 pages 10.54 Kb
Page 17
Image 17

maintenance

NOTICE

Dispose used vibrator head oil in accordance with city, local and state environmental guidlelines.

3.Fill vibrator head body with SAE 15 or AW MV ISO 46 type oil or equivalent.

4.DO NOT fill head body beyond capacity. Reference Table 6.

NOTICE

DO NOT overfill. Too much oil in the vibrator head will overload the drive motor.

 

Table 6. Vibrator Head Oil

 

 

Capacity

120 Volt

240 Volt

 

Oil Capacity.

Models

Models

 

oz. (ml)#

MGX12325

MGX22325

 

2.4 (70)

 

 

 

 

MGX12810

MGX22810

 

0.5 (15)

 

 

 

 

MGX12825

MGX22825

 

2.4 (70)

 

 

 

 

MGX13225

MGX23225

 

2.4 (70)

 

 

 

 

MGX13810

MGX23810

 

0.5 (15)

 

 

 

 

MGX13825

MGX23825

 

2.4 (70)

 

 

 

 

2.Replace vibrator shaft/head assembly if head diameter is at maximum wear as specified in Table 7. See Table 2 for available models and specifications. Shaft/head assemblies should be replaced by a qualified technician.

 

Table 7. Vibrator Head Wear Diameter

120 Volt

240 Volt

New Head

Head Dia.

w/ Max Wear

Models

Models

Dia. in. (mm)#

in. (mm)

 

 

 

 

 

 

 

MGX12325

MGX22325

.905 (23)

.842 (21.39)

 

 

 

 

MGX12810

MGX22810

1.1 (28)

1.02 (25.91)

 

 

 

 

MGX12825

MGX22825

1.1 (28)

1.02 (25.91)

 

 

 

 

MGX13225

MGX23225

1.25 (32)

1.16 (29.46)

 

 

 

 

MGX13810

MGX23810

1.5 (38)

1.39 (35.31)

 

 

 

 

MGX13825

MGX23825

1.5 (38)

1.39 (35.31)

 

 

 

 

shaft lubrication (200 Hours)

1.Place the vibrator on a suitable workbench. Make sure the area is clear of clutter.

2.Turn the plasticcoupler holding the shaft to the motor clockwise until completely loose (Figure 9). If the coupler does not come off easily, place motor in a vise and hit the coupler with a rubber mallet to loosen.

vibrator head wear (300 Hours)

1.Periodically measure the outside diameter (Figure 8) of the vibrator head casing.

VIBRATOR HEAD

CASING DIAMETER

Motor

Plastic Coupler

Figure 8. Vibrator Head Diameter Figure 9. Loosening Shaft Coupler

3.Gently pull out flexible shaft collar to access the flex shaft core crimp. See Figure 10.

mgx Series • operation and parts manual — rev. #0 (03/26/12) — page 17

Page 17
Image 17
Multiquip MGX manual Shaft lubrication 200 Hours, Vibrator head wear 300 Hours