Multiquip MP275E3, MP25E3, MP24 Connecting the Power Figure, MP2 Saw is now ready for wet cutting

Models: MP25E1 MP24 MP275E3 MP25E3

1 38
Download 38 pages 15.36 Kb
Page 20
Image 20

PRE-SETUP (ELECTRIC MOTORS)

Connecting the Power (Figure 10)

1.Place the power ON/OFF switch (Figure 11) in the OFF position (down).

Figure 11. Power ON/OFF Switch (OFF)

2.Connect an extension cord (Figure 13) of adequate current carrying capacity to the power plug on the electric motor.

DANGER - Electrocution Hazard

NEVER grab or touch a live power cord with wet hands, the possibility exists of electrical shock, ectrocution, and even death!

NEVER use a damaged or worn extension cable when connecting

to a power source. Defective cables may cause damage to the saw's electric motor or electrical shock.

CAUTION - Dry Cutting &Water Pump

MAKE CERTAIN that the correct size extension cord is used.Undersize wires will burn out motors.UseTable 4 to determine the correct extension cord size.

CAUTION - Grounding Electric Motors

ALWAYS use a grounded (3-wire)extension cord and MAKE CERTAIN that the motor is connected to a properly grounded electric circuit. If possible use a ground fault circuit interrupter to protect the operator from possible electric shock.

4.The MP2 Saw is now ready for wet cutting.

Dry Cutting (Electric Saws Only)

1.Un-plug the water pump power cord from the outlet receptacle on the electric motor conduit box.

CAUTION - Dry Cutting & Water Pump

NEVER dry cut with the pump connected to a AC power source. Running the pump dry will damage the pump. Always disconnect the pump's power cord when dry cutting.

2.The MP2 Masonry Saw is now ready for dry cutting.

TABLE 4. EXTENSION CORD SIZES

MOTOR

VOLTAGE

50'

75'

100'

 

LONG

LONG

LONG

 

 

 

 

 

 

 

 

 

 

5HP - SINGLE PHASE

230

No. 10

No. 8

No. 6

 

 

 

 

 

 

 

5HP - 3 PHASE

230

No. 12

No. 10

No.. 8

 

 

 

 

 

 

 

5HP - 3 PHASE

460

No. 14

No. 12

No. 10

 

 

 

 

 

 

 

7.5HP - 3 PHASE

230

No. 10

No. 8

No. 6

 

 

 

 

 

 

 

7.5HP - 3 PHASE

460

No. 12

No. 10

No. 8

 

 

 

 

 

 

 

 

 

 

 

 

 

PAGE 20 — MQ MP2 SERIES SAW — OPERATION MANUAL — REV. #0 (01/26/09)