INSPECTION

CAUTION

DO NOT overfill hydraulic oil tank. This could cause oil leaks and sluggish operation. Clean cap and surrounding area before opening to prevent dirt from entering oil tank.

5.When adding hydraulic oil, only fill to the specified oil level as marked on the front of the hydraulic oil tank (Figure 9). DO NOT overfill

Figure 9. Oil Tank (Front View) Checking the Air Cleaner

1.To check the engine oil level, place the compactor on secure level ground with the engine stopped.

2.Loosen the wing nut (Figure 10), remove the air cleaner cover.

Figure 10. Air Cleaner Element

3.Remove the air cleaner element (Figure 11) and inspect it for signs of wear or dirt. If air cleaner element is dirty, clean or replace element.

Figure 11. Air Cleaner Element

DANGER

EXPLOSIVE FUEL!

Motor fuels are highly flammable and can be dangerous if mishandled. DO NOT smoke while refueling. DO NOT attempt to refuel if the engine is hot or running.

Checking The Fuel

1.Remove the fuel cap located on top of fuel tank.

2.Visually inspect to see if fuel level is low. If fuel is low, replenish with diesel fuel (Figure 12).

3.When refueling, be sure to use a strainer for filtration. DONOT top-off fuel. Wipe up any spilled fuel.

Figure 12. Refueling

MVH306D/DS PLATE COMPACTOR — OPERATION AND PARTS MANUAL — REV. #11 (02/04/14) — PAGE 17

Page 17
Image 17
Multiquip MVH-306DS manual Explosive Fuel, Checking The Fuel