FLOAT SWITCHES
Float Switches
For unattended operation of the submersible pump two single fl oat switches (Model
Mounting The Float Switches
1.Determine the required cord tether length as shown in Figure 3 and Table 2.
2.Place the cord into the clamp as shown in Figure 6.
3.Secure the clamp to the discharge hose as shown in Figure 6. DO NOT install cord under hose clamp.
4.Using a screwdriver, tighten the hose clamp. DO NOT over- tighten. Make sure the fl oat cord is not allowed to touch the excess hose clamp band during operation.
EXTERNAL
POWER SOURCE
| CIRCUIT | |
| BREAKER | |
L1 | RED | |
| WHITE | |
L2 | BLACK | |
GREEN | ||
L3 | ||
| GND. |
INPUT POWER
TO CONTROL BOX
CAUTION!
HIGH
VOLTAGE!
CONTROL
BOX
RESET
CB12/14
PUMP POWER
CABLE
FLOAT SWITCH
CABLES (2)
DISCHARGE
HOSE
3.5in. (9 cm.)
MINIMUM
TETHER LENGTH
PUMP
ON
MODEL
FLOAT SWITCH (2)
PUMPING
RANGE
PUMP
OFF
SUBMERSIBLE |
PUMP |
Figure 6. Float Switch Application
ST4125G/ST6125G SUBMERSIBLE PUMP• OPERATION MANUAL — REV. #0 (11/18/10) — PAGE 13