CB12/CB14 CONTROL BOX POWER CONNECTIONS
3-Phase Power Installation (Input to Control Box)
1.The
2.Remove the
Table 6. 3Ø-230/460 VAC
Input Power Connections
Wire Color | Input Power | |
Terminal Block | ||
| ||
RED | L1 | |
WHITE | L2 | |
BLACK | L3 | |
GREEN | GROUND |
3.Tighten the connector housing to ensure a tight fi t between the power cord and the connector body. This will prevent the cable from pulling out of the terminal block and also prevent moisture from entering the control box.
4.Connect the other end of the
NOTICE
It is recommended that the power being supplied to the control box ALWAYS be connected to a circuit breaker or a quick disconnect switch.This safety feature allows for quick removal of power from the control box in the event of an emergency.
3-Phase Power Installation (Output To Pump)
1.The
2.Remove the
Table 7. 3Ø-230/460 VAC
Output Power Connections
Wire Color | Output Power | |
Overload Relay | ||
| ||
RED | T1 | |
WHITE | T2 | |
BLACK | T3 | |
GREEN | GROUND |