Multiquip ST6125G, ST4125G operation manual Pump Placement, Control Box Operation Manual Mode

Models: ST6125G ST4125G

1 28
Download 28 pages 30.45 Kb
Page 20
Image 20
OPERATION

OPERATION

Pump Placement

1.Attach a suitable lifting chain to the eye bolts (Figure 10) on the pump. Use a crane, or similar lifting device and lower the pump into place. For applications where there is an excessive amount of mud, grit or silt, the use of a support platform is desirable.

2.Make sure the pump is always placed in an upright position, not tilted (Figure 11). Never position the pump directly on a soft, loose bottom. To attain maximum pumping capacity and prevent excessive wear, position the pump so it will not burrow itself into sand or clay.

LOWER

4 or 6-INCH

DISCHARGE

HOSE

LOWER

LIFTING

CHAIN CONNECT

TO CONTROL

BOX

POWER

Pump Placement CORD

SUPPORT

PLATFORM

Figure 11. Tilted Position (Incorrect)

Control Box Operation (Manual Mode)

Figure 10. Placing the Submersible Pump

(Correct Upright Position)

PAGE 20 — ST4125G/ST6125G SUBMERSIBLE PUMP • OPERATION MANUAL — REV. #0 (11/18/10)