TLG-12SPX4 — GENERATOR CONTROL PANEL

The definitions below describe the controls and functions of the Generator Control Panel (Figure 4).

1.Frequency Meter – Indicates the output frequency in hertz (Hz). Normally 60 Hz.

2.AC Ammeter – Indicates the amount of current the load is drawing from the generator.

3.ACVoltmeter – Indicates the output voltage present at the Output Receptacles.

4.Voltage Regulator Control – Allows ±15% manual adjustment of the generator’s output voltage.

5.Engine Warning Display Module – This module displays the following engine failures:

A.Overheat Lamp – This lamp goes ON when the coolant is over 239oF. If the lamp goes ON during normal operation of the generator, the generator will immediately stop. Check for possible trouble before restarting engine.

B.Low Oil Pressure Lamp – During normal operation of the generator this lamp

should remain OFF. After the oil pressure rises after start-up, the lamp will go OFF. This lamp goes ON when the oil presure drops below

7.1 PSI.If this lamp is ever lit (ON) during normal operation of the generator, the generator will immediately shutdown. Check for possible trouble before restarting engine.

C.Low Battery Fluid Lamp – This lamp goes ON when the battery fails to charge. If this lamp goes ON during normal operation of the generator, stop the engine and fill the battery with distilled water to the specified level.

D.Pre-Heat Lamp – This lamp indicates when the engine is ready for starting during cold weather operating condition.

6.Hour Meter – Indicates the number of hours machine has been in use.

7.Fuel Guage – Indicates the amount of fuel in the Generator.

8.Ignition Switch – Insert ignition key into this switch to start engine.

9.Throttle Lever – This knob controls the speed of the engine.

10.Ground Terminal - Ground terminal for Output Receptacles.

11.GFCI Receptacle – Provides 120 VAC output (20 amps max).

12.Auxillary Receptacle (for L5-30R)Provides 120VAC output (30 amps max).

13.Auxillary Receptacle (for L6-30R)Provides 240VAC output (30 amps max).

14.Twist Lock Dual Voltage Receptacle (CS6369) – Provides 120/240 VAC output (50 amps max).

18.Main Circuit Breaker – This three-pole, 50A main breaker is provided to protect the the Output Receptacles from overload.

PAGE 20 — TLG-12SPX4— OPERATION AND PARTS MANUAL — REV. #1 (12/17/09)

Page 20
Image 20
Multiquip operation manual TLG-12SPX4 Generator Control Panel

TLG-12SPX4 specifications

The Multiquip TLG-12SPX4 is a premier choice in the realm of portable generators, designed to deliver reliable power for a variety of applications. As the demand for efficient and mobile power sources continues to rise, the TLG-12SPX4 stands out with a host of innovative features and advanced technologies that cater to both professional and recreational uses.

One of the main features of the TLG-12SPX4 is its robust power output. The generator is equipped with a powerful engine capable of producing up to 12,000 watts of peak power. This makes it suitable for construction sites, outdoor events, and emergency situations, where dependable electricity is crucial. The generator’s impressive output ensures that multiple tools and appliances can operate simultaneously without any drops in performance.

In terms of design, the Multiquip TLG-12SPX4 boasts a durable and heavy-duty frame that is built to withstand the rigors of job sites and harsh weather conditions. The unit is also equipped with a weather-resistant cover to protect its components from the elements, ensuring longevity and reliability. Its compact size and wheel kit allow for easy transport, making it a favored choice for contractors and outdoor enthusiasts alike.

The technology embedded in the TLG-12SPX4 enhances its user-friendliness and efficiency. It features a digital display that provides real-time information such as voltage output, power consumption, and runtime. This allows users to monitor their power usage closely. Additionally, the electric start system simplifies operation, eliminating the need for tedious manual starting procedures.

Safety is another paramount aspect of the TLG-12SPX4 design. The unit comes equipped with automatic low-oil shutdown technology, which protects the engine from damage by automatically shutting off when oil levels are critically low. Circuit breakers are also integrated to prevent overloads, ensuring safe operation for users.

In conclusion, the Multiquip TLG-12SPX4 is a powerful, durable, and user-friendly generator that exemplifies what modern portable power solutions should provide. With its impressive output, robust construction, advanced technologies, and thoughtful safety features, it stands ready to meet the diverse power needs of its users, whether on a job site or in a home emergency situation. Its combination of efficiency and reliability makes it a top choice among generators in its class.