Coolant (Antifreeze/Summer Coolant/Water)

KUBOTA recommends antifreeze/summer coolant for use in their engines, which can be purchased in concentrate (and mixed with 50% demineralized water) or pre-diluted. See the KUBOTA Engine Owner's Manual for further details.

TLG-12SPX4 — SETUP

Cleaning the Radiator

The engine may overheat if the radiator fins become overloaded with dust or debris. Periodically clean the radiator fins with compressed air. Cleaning inside the machine is dangerous, so clean only with the engine turned off and the negative battery terminal disconnected.

WARNING - BURN HAZARDS

If adding coolant/antifreeze mix to the radiator, DO NOT remove the radiator cap until the unit has completely cooled.The possibility of hot! coolant exists which can cause severe burns.

Day-to-day addition of coolant is done from the recovery tank. When adding coolant to the radiator, DO NOT remove the radiator cap until the unit has completely cooled. See Table 9 for engine, radiator, and recovery tank coolant capacities. Make sure the coolant level in the recovery tank is always between the "H" and the "L" markings.

Table 9. Coolant Capacity

Engine and Radiator

1.85 Gal. (7.0 liters)

 

 

Reserve Tank

.264 Gal (1.0 liters)

 

 

Operation FreezingWeather

When operating in freezing weather, be certain the proper amount of antifreeze (Table 10) has been added.

Table 10. Anti-Freeze

Operating Temperatures

Vol %

Freezing Point

 

 

Anti-Freeze

 

 

°C

°F

 

 

 

 

50

-37

-34

 

 

 

Air Cleaner

Periodic cleaning/replacement is necessary. Inspect it in accordance with the KUBOTA Engine Owner's Manual.

Fan Belt Tension

A slack fan belt may contribute to overheating, or to insufficient charging of the battery. Inspect the fan belt for damage and wear and adjust it in accordance with the

KUBOTA Engine Owner's Manual.

The fan belt tension is proper if the fan belt bends 10 to 15

mm(Figure 18) when depressed with the thumb as shown below.

Figure 18. Fan Belt Tension

CAUTION - ROTATING PARTS

NEVER place hands near the belts or fan while the generator set is running.

NOTE

When the antifreeze is mixed with

water, the antifreeze mixing ratio

 

 

must be less than 50%.

TLG-12SPX4— OPERATION AND PARTS MANUAL — REV. #1 (12/17/09) — PAGE 27

Page 27
Image 27
Multiquip TLG-12SPX4 Coolant Antifreeze/Summer Coolant/Water, Cleaning the Radiator, Operation FreezingWeather

TLG-12SPX4 specifications

The Multiquip TLG-12SPX4 is a premier choice in the realm of portable generators, designed to deliver reliable power for a variety of applications. As the demand for efficient and mobile power sources continues to rise, the TLG-12SPX4 stands out with a host of innovative features and advanced technologies that cater to both professional and recreational uses.

One of the main features of the TLG-12SPX4 is its robust power output. The generator is equipped with a powerful engine capable of producing up to 12,000 watts of peak power. This makes it suitable for construction sites, outdoor events, and emergency situations, where dependable electricity is crucial. The generator’s impressive output ensures that multiple tools and appliances can operate simultaneously without any drops in performance.

In terms of design, the Multiquip TLG-12SPX4 boasts a durable and heavy-duty frame that is built to withstand the rigors of job sites and harsh weather conditions. The unit is also equipped with a weather-resistant cover to protect its components from the elements, ensuring longevity and reliability. Its compact size and wheel kit allow for easy transport, making it a favored choice for contractors and outdoor enthusiasts alike.

The technology embedded in the TLG-12SPX4 enhances its user-friendliness and efficiency. It features a digital display that provides real-time information such as voltage output, power consumption, and runtime. This allows users to monitor their power usage closely. Additionally, the electric start system simplifies operation, eliminating the need for tedious manual starting procedures.

Safety is another paramount aspect of the TLG-12SPX4 design. The unit comes equipped with automatic low-oil shutdown technology, which protects the engine from damage by automatically shutting off when oil levels are critically low. Circuit breakers are also integrated to prevent overloads, ensuring safe operation for users.

In conclusion, the Multiquip TLG-12SPX4 is a powerful, durable, and user-friendly generator that exemplifies what modern portable power solutions should provide. With its impressive output, robust construction, advanced technologies, and thoughtful safety features, it stands ready to meet the diverse power needs of its users, whether on a job site or in a home emergency situation. Its combination of efficiency and reliability makes it a top choice among generators in its class.