MultiModemBA User Guide

Command

Values

Description

Sr?

r = 0-11, 13,

Reads value of Register “r” and displays

 

15-19, 24-26,

value in 3-digit Decimal format.

 

30, 32 or 34...

 

$SBn

n = speed

2834 Series:

 

 

$SB300 selects 300 bps at serial port.

 

 

$SB1200 selects 1200 bps at serial port.

 

 

$SB2400 selects 2400 bps at serial port.

 

 

$SB4800 selects 4800 bps at serial port.

 

 

$SB9600 selects 9600 bps at serial port.

 

 

$SB19200 selects 19,200 bps at serial port.

 

 

$SB38400 selects 38,400 bps at serial port.

 

 

* $SB57600 selects 57600 bps at serial port.

 

 

$SB115200 selects 115200 bps at serial port.

 

 

1432 Series:

 

 

$SB300 selects 300 bps at serial port.

 

 

$SB1200 selects 1200 bps at serial port.

 

 

$SB2400 selects 2400 bps at serial port.

 

 

$SB4800 selects 4800 bps at serial port.

 

 

$SB9600 selects 9600 bps at serial port.

 

 

$SB19200 selects 19,200 bps at serial port.

 

 

$SB38400 selects 38,400 bps at serial port.

 

 

* $SB57600 selects 57600 bps at serial port.

 

 

932 Series:

 

 

$SB300 selects 300 bps at serial port.

 

 

$SB1200 selects 1200 bps at serial port.

 

 

$SB2400 selects 2400 bps at serial port.

 

 

$SB4800 selects 4800 bps at serial port.

 

 

$SB9600 selects 9600 bps at serial port.

 

 

$SB19200 selects 19,200 bps at serial port.

 

 

* $SB38400 selects 38400 bps at serial port.

&SFn

n = 0 or 1

* &SF0 selects DSR follows CD.

 

 

&SF1 selects DSR independent.

&Sn

n = 0, 1 or 2

&S0 forces Data Set Ready On.

 

 

* &S1 lets Data Set Ready act normally.

 

 

&S2 Data Set Ready drop is regulated by S24 on

 

 

disconnect.

$SPn

n = 0 or 1

* $SP0 disables UUCP Spoofing

 

 

$SP1 enables UUCP Spoofing

T

 

Modem will tone-dial numbers following the T.

&Tn

n = 4 or 5

&T4 means Enable Response to Request for

 

 

Remote Digital Loopback.

 

 

* &T5 means Disable Response to Request for

 

 

Remote Digital Loopback.

#Tn

n = 0 or 1

#T0 turns off Trellis Coded Modulation

 

 

* #T1 turns on Trellis Coded Modulation

* Factory Default Setting

136

Page 136
Image 136