Figure 2-1: Connection Wiring Directly to Central Heating Circulator

 

 

 

 

DIAGRAM "A"

 

 

WIRING DIAGRAM CONNECTING TO CIRCULATOR

 

 

GREEN (GROUND)

 

 

WHITE (NEUTRAL)

 

 

 

BLACK

 

BROWN (NEUTRAL)

GREEN (GROUND)

NORMALLY OPEN

ORANGE (HOT)

 

THERMOSTAT

 

CONNECTION

 

GRAY

 

T

 

 

 

WHITE

 

 

 

 

(NEUTRAL)

T

GRAY

 

 

 

BLACK

 

 

 

 

(HOT)

 

 

 

 

 

 

 

 

 

 

GREEN

 

 

 

 

 

(GROUND)

 

 

 

 

ELECTRICAL

 

 

 

SWITCH JUNCTION BOX

 

 

 

 

120V 60 HZ

Figure 2-1: Connection Wiring Directly to Central Heating Circulator

ZONE

 

 

 

 

THERMOSTAT

 

 

 

 

R845A

 

 

 

BOILER

SWITCHING

 

 

 

 

 

 

"TT"

RELAY ZONE

 

 

 

 

 

 

GRAY

 

 

 

 

1K1

 

5

3

 

 

 

 

T

 

 

 

 

T

 

 

 

 

 

 

1K1

1K2

 

1

2

6

4

BOILER

"TT"

 

 

 

 

GRAY

 

 

 

ZONE

 

L1 HOT (BLACK)

 

 

CIRCULATOR

 

 

 

 

 

120 VOLT

 

 

 

 

L2 NEUTRAL

 

 

 

(WHITE)

 

 

 

Figure 2-3: For circulator amp loads greater than 4 amps (3 amps for “HA” models) use the wiring diagram shown at left. The brown and orange wires will not be used in this application.

 

 

 

 

 

ELECTRICAL

 

 

 

DIAGRAM "B"

 

WIRING DIAGRAM WITHOUT CONNECTION TO CIRCULATOR

 

 

ORANGE BROWN GREEN

IMPORTANT NOTE:

 

 

BE CERTAIN THAT THE ORANGE

 

 

WIRE IS SECURELY CAPED.

 

 

FAILURE TO DO SO COULD

 

 

 

 

 

RESULT IN INJURY OR FIRE

 

 

 

 

 

AND COULD DAMAGE THE CONTROL.

NORMALLY OPEN

ORANGE (HOT)

BROWN (NEUTRAL)

GREEN (GROUND)

 

 

THERMOSTAT

 

 

CONNECTION

 

T

GRAY

WHITE

GRAY

(NEUTRAL)

T

BLACK

 

(HOT)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GREEN

 

 

 

 

 

(GROUND)

 

 

 

 

 

GROUND

 

 

 

 

 

BUS

 

 

 

 

ELECTRICAL

 

 

SWITCH JUNCTION BOX

 

 

 

 

120V 60 HZ

Figure 2-2: Connection Wiring without Wiring Central Heating Circulator

Note to Electrical Contractor: The orange wire is 120 Volt/4 Amp maximum for central heating circulator only. Loads greater than 4 amps or 3 amps for HA models only will blow the fuse on the board. The brown wire is the neu- tral wire for the central heating pump only.