Murphy LS200N, L1100 manual Instructions, Dvo, Adjustable Orifice, Section, 00-02-0563, 01-11-06

Models: L1100 LS200 LS200N

1 20
Download 20 pages 47.04 Kb
Page 12
Image 12
Instructions

Instructions

1.Block off and bleed the instrument gas pressure supply to the LS200NDVO/DVOR.

2.Remove the tubing between the LS200NDVO/DVOR and the scrubber dump valve, and remove the supply gas tubing (regulator [-R-] if used).

3.Remove the LS200NDVO/DVOR from the vessel (optional).

4.If the LS200NDVO/DVOR was removed from the vessel, mount it in a suitable vise on a work bench (if possible).

5.Using the proper tools, disconnect the Inlet, Outlet, and Exhaust fittings from the existing DVO. See Figure 1. You will re-connect these to the new DVO in a later step.

NOTE: The following steps must be done with the DVO in the upright position (on top of the LS200NDVO).

6.Remove the LS200NDVO/DVOR cover. The use of a strap wrench or a pipe wrench may be needed.

7.With a 9/16” hex wrench, loosen the hex head bolt on top of the DVO and remove the existing DVO from the body.

8.Ensure that the adjustable orifice is fully raised up so that the actuator arm is not bent when inserted into the body. See Figure 2.

9.Insert the new DVO onto the body. The DVO manual valve operator must face away from the vessel. See Figure 3.

Figure 1 - DVO

Figure 2 – Adjustable Orifice

Section 15

00-02-0563

01-11-06

- 8 -

Page 12
Image 12
Murphy LS200N, L1100 manual Instructions, Dvo, Adjustable Orifice, Section, 00-02-0563, 01-11-06