Musical Fidelity A3.2 CR manual Troubleshooting, Problem, Possible Cause, Remedy

Models: A3.2 CR

1 7
Download 7 pages 41.81 Kb
Page 6
Image 6
TROUBLESHOOTING

TROUBLESHOOTING

Basic problem solving with an amplifier is similar to troubleshooting any other electrical or electronic equipment. Always check the most obvious possible causes first. To give you a few ideas of what to look for, check the following:

Problem

Possible Cause

Remedy

No power when MAINS

Mains plug not inserted

Plug in securely

POWER switch is operated

fully into rear socket

 

No sound

Tape monitor function has

Switch off tape monitor

 

been selected on the pre-

at the pre-amplifier

 

amplifier

 

 

Wrong connections between

Check audio input lead

 

pre-amplifier and the A3.2 CR

connections

 

Speakers not connected, or

Check speaker cables

 

incorrectly wired

 

The sound is not precise,

Speakers are connected out of

Ensure method of conn-

lacking bass and stereo

phase, i.e. connections to one-

ection is the same for left

image

speaker (+ and -) are reversed

and right speakers

 

 

 

If none of these actions effect a cure, please contact your dealer, or an authorised Musical Fidelity service agent. Remember, never open the case of the A3.2 CR Power amplifier your- self, as this will invalidate the guarantee.

Issue 1: April 2002

A3.2 C R Power

Instructions for Use Page 6 of 7

Page 6
Image 6
Musical Fidelity A3.2 CR manual Troubleshooting, Problem, Possible Cause, Remedy