6)Check that the new inflator body indicator is green. Insert the new

inflator body with CO2 cylinder pointing upward inside the Inflatable PFD (Fig. 17). Let the sealing ring rest on the adapter around the four lugs.

FIGURE 17

 

Green Indicator

Caution:

 

Do not turn

 

the center

 

shaft

7)Now check the new manual/automatic cap as follows (Fig. 18):

1.Is the single point status indicator showing green?

2.Is the expiry day OK?

If YES is the answer to both questions, then proceed as follows. If the answer is NO to either question, get a new cap.

FIGURE 18

Water

Inlet

Valve

Single

Point

Indicator

Expiry

8)Hold the CO2 cylinder through the fabric of the Inflatable Vest with LIFTTM (Fig. 19). Position the replacement cap with the water inlet valve pointing to the right and press firmly onto the inflator body