2)Put on the Inflatable Vest with LIFTTM.

3)Actuate the inflation system by jerking firmly downward on the pull-tab. The Inflatable Vest with LIFTTM should fully inflate within 5 seconds.

4)Get into shallow water, just deep enough that you can stand with your head above the surface.

5)See if the Inflatable Vest with LIFTTM will float you on your back or just slightly back of vertical. In a relaxed floating position, verify that your mouth is well above the water’s surface. Note the effect of where you hold your legs and how you float.

6)Get out of the water and remove the Inflatable Vest with LIFTTM. Completely deflate the Inflatable Vest with LIFTTM using the oral inflator (see Deflation p. 11).

7)Let the Inflatable Vest with LIFTTM dry thoroughly. Re-arm (p. 13) and Repack the PFD (p. 17).

HOW DO YOU TEST YOUR PFD USING THE ORAL INFLATOR?

This test is not mandatory, however may be conducted using the following procedure.

WARNING: Use only a previously fired hydrostatic inflator to perform this test . DO NOT test with a fully armed hydrostatic inflator as double inflation may occur, possibly resulting in cell damage.

1)No spare parts or re-arming kits are needed to test your Inflatable PFD.

2)Put on the Inflatable Vest with LIFTTM.

3)Get into shallow water, just deep enough that you can stand with your head above the surface.

4)If you are a weak swimmer or non-swimmer, inflate the Inflatable

Inflatable Vest with LIFTTM Owner’s Manual

32

Page 35
Image 35