Mustang Survival MD0450 Uninspected Commercial Vessel Use, Component Inspection Instructions

Models: MD0450

1 42
Download 42 pages 36.03 Kb
Page 8
Image 8

FIGURE 2 Hydrostatic Inflator Cap

Water Inlet Valve

 

Black Locking Ring

 

Yellow Inflator Cap

 

Cap/Locking Ring

Single

Tabs

Lanyard

Point

Status

 

Indicator

Inflator

 

 

Body

 

Expiry

 

Date

 

Manual Inflation

 

Pull-tab

Uninspected Commercial Vessel Use

This Inflatable PFD is not approved for “hot work” and care must be taken to avoid damage from abrasion and sharp objects.

Component Inspection Instructions

1)Examine the single point indicator through the window panel. Ensure the single point indicator is green. If the single point indicator is red, the mechanism has been fired or is incorrectly fitted (Fig. 2). See RE-ARMING YOUR PFD (p. 13).

NOTE: The single point indicator must be green before proceeding.

2)Open the cover at wearer’s right-hand side of the chest and lay the device flat.

3)Ensure the oral-inflation dust cap is in the stowed position (Fig. 22).

4)Ensure the single point indicator is green and the pull-tab lanyard is hanging on the outside; secure the zippers on the Inflatable Vest with LIFTTM (see Repacking, p. 17).

5)Ensure the date on the inflator is not five years or older (Fig. 2). If it