Mustang Survival MD0450 manual Vi Ensure the single point status indicator is green Fig

Models: MD0450

1 42
Download 42 pages 36.03 Kb
Page 32
Image 32

ii)Oral Inflation Valve Test: To check the oral inflation valve, fully inflate the Inflatable Vest with LIFTTM using the oral inflator and hold valve under water. If bubbles appear, deflate and re-inflate to test again. Should the leak persist, take your Inflatable Vest with LIFTTM to your Mustang dealer for evaluation and/or servicing.

CAUTION: To avoid accidental inflation, don't allow the water to contact the hydrostatic inflator.

iii)Perform a thorough visual examination. See Readiness Checklist (p. 6).

Perform these tests more often if exposed to potential damage or used in extreme conditions.

3)After Each Inflation - Re-arm the Inflatable Vest with LIFTTM. See Re-arming Your PFD, p. 13.

4)Annually - Perform the following at the beginning of each boating season, after inflation, or whenever the integrity of the Inflatable Vest with LIFTTM is in doubt:

i)Check all components for dirt or corrosion. Clean or replace, as neccessary. See Readiness Checklist (p. 6).

ii)Visually examine your Inflatable Vest with LIFTTM for damage or excessive abrasion, wear, tear or contamination. Particular attention must be paid to the stitching, straps and hardware. If in doubt, send it to your Mustang dealer for evaluation and/or servicing.

iii)Perform the Leak Test. See the Leak Test (section 2) i) in the Care and Maintenance Instructions).

iv)Perform the Oral Inflation Valve Test: See the Oral Inflation Valve Test (section 2) ii) in the Care and Maintenance Instructions).

v)Ensure the current date is not past the date on the inflator. If it is, replace the inflator (see Re-arming Your PFD, p. 13).

vi)Ensure the single point status indicator is green (Fig. 2).

vii)Record as an "Annual" inspection in permanent ink on the Care and Storage label, in the Date Maintained column.

29

MUSTANG SURVIVAL

Page 32
Image 32
Mustang Survival MD0450 manual Vi Ensure the single point status indicator is green Fig