Mustang Survival MSV971 Life Preserver and Survival Vest

Description and Maintenance Instructions

9 June 2004, Rev: 1.0

Figure 21. Step a. Replace Inflatable Cell

Self-locking Tie

b.Remove the oral inflator valves and CO2 inflation device from the cell.

c.Reinstall the components removed from the non-serviceable cell onto the replacement cell.

d.Perform the Inflatable Cell Test detailed in Section 5.7.

e.Re-attach the serviceable cell to the protective container with the cell anchor strip. Referring to figures 4 and 22 and starting at the right side, thread the aramid cord loops of the protective container through the grommets of the cell anchor strips. Pass the first cord loop over the top of the second loop and so forth, forming an interlocking arrangement as shown.

Figure 22. Step f. Replace Inflatable Cell

28

This document is for information purposes only. It is not a controlled

 

document and may not be considered current when printed.

Page 31
Image 31
Mustang Survival MSV971 manual Step a. Replace Inflatable Cell Self-locking Tie