Page 5
Image 5
executed by pressing the Ubutton.

KEYPAD CONTROLS & INDICATORS

Window. Lights indicate system status messages; digit display indicates related zone, function or error message numbers.

STATUS Light. Lights (green) to indicate that the system is ready for arming. If a zone is not secured the light will be off and the zone will display in the window. If a zone has been bypassed, the STATUS light will blink while armed.

ARMED Light. Lights (red) to indicate that the system is armed. If an alarm has occurred, the ARMED LED will be flashing.

MENU Button. Selects available system functions as displayed in the window. The selected function is

executed by pressing the Ubutton.

BYPASS Button. (1) Deactivates selected zones from the system. (2) Unbypasses a bypassed zone. (GEM- P3200/9600 panels only).

RESET Button. (1) Resets various

system troubles, displays, etc. (See text.) (2) Resets residential smoke detectors.

Numerical Keys (1-9, 0). Used to enter codes, zone numbers, etc.

ENTER Button. Entry key. Causes the entered code or selected function to be executed.

STAY Button. (1) Bypasses all Interior Zones simultaneously ("STAY Mode") to allow free movement within the premises. Hold down P

when the system is armed in "STAY Mode" to cancel entry delay on Exit/ Entry Zones, causing an instant alarm upon violation. (2) Scrolls the window display forward (NEXT). (3) Answers “YES” to questions in the window display.

AWAY Button. (1) Arms all zones in the system. (2) Scrolls window display backward (PRIOR). (3) Answers “NO” to questions in the window display.

AREA Button (G). Selects other

areas and is used with emergency buttons.

Emergency Buttons. Used with the G butt o n t o s ig n a l an

emergency, as follows:

Press the 7and the G buttons for Fire Emergency.

Press the 8and the G buttons for Auxiliary Emergency.

Press the 9and the G buttons for Police Emergency.

AC On Indicator. Indicates AC Power is present.

Chime. Indicates door chime is turned on.

System Status Messages. Mes- sages appear in display window when active. Includes RESET, FIRE,

TROUBLE, INSTANT, INTERIOR, CANCELLED, and BYPASS.