![HSystem Troubles](/images/new-backgrounds/43929/4392923x1.webp)
HSystem Troubles
The
and beeping the keypad buzzer. If you cannot immediately clear the system trouble, the system can still be used. Simply press Dto view the trouble as described below, and then arm the system.
In order to determine the nature of the trouble, press D, count the number of keypad beeps and ob-
serve the number of the illuminated zone light. Refer to the following table to determine the cause of the trouble. If there is more than one trouble to be viewed, pressing Dwill scroll to the next, and then exit
the HSYSTEM mode if there are no additional troubles to view.
| Keypad Beeps or | Zone light | System Trouble | Action |
|
| ON | Condition |
|
|
|
|
|
|
| 1 Beep with Y | 1 | AC Power Failure | This trouble will occur if AC power is not present. Make sure |
| flashes |
|
| system transformer is plugged into AC receptacle and check |
|
|
| circuit breaker, otherwise call installing company for service. | |
|
|
|
| |
| 1 Beep | 2 | Low Battery | If there has been a recent power failure, the battery may be |
|
|
|
| partially depleted and must be recharged by the control panel. |
|
|
|
| If the trouble does not go away in 24 hours, call installing com- |
|
|
|
| pany for service. |
| 1 Beep | 3 | Communication | The system was not able to report to central station. If this is |
|
|
| Failure | due to a temporary interruption in the telephone service, the |
|
|
|
| trouble can be cleared when the service is restored by press- |
|
|
|
|
|
| 1 Beep | 4 | Telephone Line Cut | The telephone line has failed. If telephone service has been |
|
|
|
| temporarily interrupted, the trouble will clear it is when re- |
|
|
|
| stored. Otherwise, call installing company for service. |
| 2 Beeps | 1 | Bell/Siren Trouble | There is a problem with the Bell or Siren. Call installing com- |
12 |
|
|