INSTALLATION WHEN INSTALLED WITH BLOWER KIT EP63

For reduced clearances installation must comply with NFPA 211or CAN/CSA-B365.

Alcove installation

Model 1600C-1 may be installed into an alcove having a depth of not more than 4 feet and a height of at least 7 feet, when using a listed double wall connector that is rated for a minimum 12” clearance to combustible material.

The minimum clearances are as shown.

Alcove installation

Listed single wall chimney connector

 

 

Flue configuration

 

 

 

 

 

Type 1

Horizontal

Vertical

 

 

 

 

 

 

 

 

 

A

16”

16”

FROM

 

 

 

 

 

 

B*

10”

16”

UNIT

 

 

 

 

 

 

 

C

11”

11”

 

 

 

 

 

 

 

 

 

D

25”

25”

FROM

 

 

 

 

 

 

E

...

18”

PIPE

 

 

 

 

 

 

 

F

...

18”

 

 

 

 

*A 18 in. Minimum clearance should be maintained from combustible wall to the chimney connector.

16"

16"

16"

4footmax

84"

Ilustratedwith.75"hearthpad.

Double walled connectors listed for a minimum clearance of 12” or less from combustible materials must be used to achieve the following clearances.

 

 

Flue configuration

 

 

 

 

 

Type 2

Horizontal

Vertical

 

 

 

 

 

 

 

 

 

A

16”

16”

FROM

 

 

 

 

 

 

B

10”

10”

UNIT

 

 

 

 

 

 

 

C

11”

11”

 

 

 

 

 

 

 

 

 

D

25”

25”

FROM

 

 

 

E

...

16”

Walls shall not extend from front of unit when installed

in the alcove configuration.

Stove installation

PIPE

 

 

F

...

12”

If the stove is to be installed on a combustible floor, it must be p l a c e d o n a a p p r o v e d non-combustible hearth pad, t h a t e x t e n d s 8 " ( 2 0 0 m m ) beyond the stove sides and back, and 18" (455mm) to the front.

8"

8"

18"

8"

F

B

D

 

 

A

C

E

C

6

Page 6
Image 6
Napoleon Fireplaces 1600C-1 specifications Installation When Installed with Blower KIT EP63