10
FINISHING
HEARTH
FIGURE 9 | A hearth is NOT necessary but is recommended for aesthetic |
| purposes. |
COLD CLIMATE INSTALLATION
! WARNING
It is MANDATORY to have an insulated wall behind the fireplace, when the fireplace is being installed on an outside wall or chase.
MANTEL
The minimum distance from the top of the unit that the mantel can be installed is 10", at any depth.
! WARNING
When using paint or lacquer to finish the mantel, the paint or lacquer must be heat resistant to prevent discoloration.
FRAMING AND FINISHING
FIGURE 10
NOTE: In order to avoid the possibility of exposed insulation or vapour barrier coming in contact with the fireplace body, it is recommended that the walls of the fi replace enclosure be “fi nished” (ie: drywall/sheetrock), as you would fi nish any other outside wall of a home. This will ensure that clearance to combustibles is maintained within the cavity.
FIGURE 11
FINISHING CHECKLIST
1.Power supply service must be completed prior to fi nishing to avoid reconstruction.
2.Fireplace vents and air openings cannot be covered in any circumstances.