10

FINISHING

HEARTH

FIGURE 9

A hearth is NOT necessary but is recommended for aesthetic

 

purposes.

COLD CLIMATE INSTALLATION

! WARNING

It is MANDATORY to have an insulated wall behind the fireplace, when the fireplace is being installed on an outside wall or chase.

MANTEL

The minimum distance from the top of the unit that the mantel can be installed is 10", at any depth.

! WARNING

When using paint or lacquer to finish the mantel, the paint or lacquer must be heat resistant to prevent discoloration.

FRAMING AND FINISHING

FIGURE 10

NOTE: In order to avoid the possibility of exposed insulation or vapour barrier coming in contact with the fireplace body, it is recommended that the walls of the fi replace enclosure be “fi nished” (ie: drywall/sheetrock), as you would fi nish any other outside wall of a home. This will ensure that clearance to combustibles is maintained within the cavity.

FIGURE 11

FINISHING CHECKLIST

1.Power supply service must be completed prior to fi nishing to avoid reconstruction.

2.Fireplace vents and air openings cannot be covered in any circumstances.

W415-0675 / A / 03.28.08

Page 10
Image 10