INSTALLATION

7

INSTALLATION

!WARNING

RISK OF FIRE! The power cord must not be pinched against a sharp edge. Secure cord to avoid tripping or snag- ging to reduce the risk of fi re, electric shock or personal injury. Do not run cord under carpeting. Do not cover cord with throw rugs, runners or the like. Arrange cord away from traffi c areas and where it will not be tripped over.

RISK OF FIRE! To prevent a possible fi re, do not block air intake or exhaust in any manner. Do not use on soft surfaces where openings may become blocked.

RISK OF FIRE! Do not blow or place insulation against the fi replace.

This electric fi replace is tested and listed for use only with the approved optional accessories. Use of optional acces- sories not specifi cally tested for this electric fi replace could void the warranty and/or result in a safety hazard.

If the information in these instructions is not followed exactly, a fi re or explosion may result causing property damage, personal injury or death. Do not store or use gasoline or other fl ammable vapors in the vicinity of this or any other fi replace.

BEFORE INSTALLATION

Select a suitable location that is not susceptible to moisture and is away from drapes, furniture and high traffi c areas. NOTE: Follow all national and local electrical codes. This

replace can be installed into either an existing fi replace opening or as new construction / renovation.

EXISTING FIREPLACE INSTALLATION

Thoroughly clean out the existing fi replace and hearth area. Plan the power supply. If an existing grounded outlet is near the fi replace, the power cord can run behind the fi re- place. If the cord is not long enough to reach the outlet, a grounded extension cord minimum AWG No. 14 and rated to a minimum of 1875 watts may be used. If you plan to cut or drill a hole in the existing fi replace for wiring, it is best to hire a professional to do this step in order to prevent personal injury. To reduce the risk of fi re, do not run the power cord under rugs, carpets, etc. Arrange the power supply cord away from high traffi c areas where it may pose a tripping hazard.

CLEARANCES TO COMBUSTIBLES

Sides

1"

Back

1"

Top

1"

 

 

NEW CONSTRUCTION OR RENOVATION

1.Select a location that is not prone to moisture and is located at least 0.9 m or 3 feet away from combustible materials such as curtains or drapes, furniture, bedding, paper, etc.

2.Place the unit in selected location to see how it will look in the future.

3.Mark the desired location on the fl oor and store unit in a safe, dry and dust free location.

4.Frame in an opening leaving at least 1/4" (6 mm) around the edge of the unit. Any new wiring must be done in com- pliance with local and national codes and other applicable regulations in order to reduce the risk of fi re, electric shock or other injuries. Therefore, it is strongly recommended that you hire a professional to complete any such work.

INSTALLING THE FIREPLACE

1.Once the site has been prepared, the fi replace can be installed.

2.Make sure the main power switch is in the "OFF" posi- tion.

3.Plug the fi replace into a 15-amp/120 Volt, grounded outlet. Use a CSA or UL approved surge protector.

4.Push in the fi replace so that the trim is against the fi n- ished mantel or wall surface.

!WARNING

This appliance must remain removable from the enclosure. The appliance may be hardwired, but it is recommended that it be plugged into a standard outlet using the supplied power cord. This appliance must not be sealed around the front facing.

Fireplace vents located on the front and back of this electric

replace cannot, in any way, be covered as it may create a fi re hazard.

W415-0675 / A / 03.28.08

Page 7