MAINTENANCE

20

MAINTENANCE

Turn off the gas and electrical power before servicing the fireplace.

CAUTION: Label all wires prior to disconnection when serv- icing controls. Wiring errors can cause improper and dan- gerous operation. Verify proper operation after servicing. This fireplace and its venting system should be inspected before use and at least annually by a qualified service per- son. The fireplace area must be kept clear and free of combustible materials, gasoline or other flammable va- pours and liquids. The flow of combustion and ventilation air must not be obstructed.

1.In order to properly clean the burner and pilot as- sembly, remove the logs to expose both assemblies.

2.Keep the control compartment, logs, burner, air shut- ter opening and the area surrounding the logs clean by vacuuming or brushing, at least once a year.

3.Check to see that all burner ports are burning. Clean out any of the ports which may not be burning or are not burning properly.

4.Check to see that the pilot flame is large enough to engulf the thermocouple and thermopile and reaches toward the burner with the third jet.

5.Replace the cleaned logs.

6.Check to see that the main burner ignites completely on all openings when the gas knob for the burner is turned on. A 5 to 10 second total light-up period is sat- isfactory. If ignition takes longer, consult your Napoleon dealer / distributor.

7.Check that the gasketing on the door is not broken or missing. Replace if necessary.

ADJUSTMENTS

PILOT BURNER ADJUSTMENT

Adjust the pilot screw to provide properly sized flame. Turn in a clockwise direction to reduce the gas flow.

FIGURE 44

FIGURE 45

 

VENTURI ADJUSTMENT

Natural gas models have air shutters set at ¼ (.250") inch open. Propane gas models have air shutters set at 3/8 (.375) inch open. Closing the air shutter will cause a more yellow flame, but can lead to carboning. Opening the air shutter will cause a more blue flame, but can cause flame lifting from the burner ports. The flame may not appear yellow immediately; allow 15 to 30 minutes for the final flame colour to be established.

FIGURE 46

AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BYA

QUALIFIED GAS INSTALLER!

W415-0100 / D / 01.13.04

Page 20
Image 20