Napoleon Fireplaces GD45-N, GD45-P VENTING OPTION #1, VENTING OPTION #2, Figures, RISE in feet

Models: GD45-N GD45-P

1 24
Download 24 pages 57.9 Kb
Page 6
Image 6
VENTING OPTION #1

6

Use the venting option charts to calculate vertical rises for horizontal runs between 3 and 20 feet.

When calculating maximum run lengths, include 10 feet for each 90° elbow or 5 feet for each 45° elbow. (DO NOT INCLUDE THE FIRST ELBOW DIRECTLY OFF THE UNIT.)

VENTING OPTION #1

Use this chart to calculate vertical rise for horizontal run between 1 foot (maximum length when the vertical rise is at its minimum of 1 foot) and 8 feet.

FIGURES 5

VERTICAL

RISE in feet

8 FT MAX (1 FT MAX)

HORIZONTAL VENT RUN

in feet

40 FT MAX

1 FT MIN

VENTING OPTION #2

Use this chart to calculate vertical rise for horizontal run between 3 feet (maximum length when the vertical rise is at its minimum of 1 foot) and 20 feet.

 

20 FT MAX

 

(3 FT MAX)

 

FIGURES 6

 

20 FT MAX

VERTICAL

1 FT MIN

RISE in feet

 

HORIZONTAL VENT RUN

When venting, the horizontal run must be kept to a

in feet

minimum of 10 inches or a maximum of 20 feet.

W415-0100 / D / 01.13.04

Page 6
Image 6
Napoleon Fireplaces GD45-N, GD45-P manual VENTING OPTION #1, VENTING OPTION #2, Figures, RISE in feet