2.3GAS INSTALLATION

10

2.3GAS INSTALLATION

!WARNING

RISK OF FIRE, EXPLOSION OR ASPHYXIATION. ENSURE THERE ARE NO IGNITION SOURCES SUCH

AS SPARKS OR OPEN FLAMES.

SUPPORT GAS CONTROL WHEN ATTACHING GAS SUPPLY PIPE TO PREVENT DAMAGING GAS LINE.

ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED. PURGING OF THE GAS SUPPLY LINE SHOULD BE PERFORMED BY A QUALIFIED SERVICE TECHNICIAN. ASSURE THAT A CONTINUOUS GAS FLOW IS AT THE BURNER BEFORE CLOSING THE DOOR. ENSURE ADEQUATE VENTILATION. FOR GAS AND ELECTRICAL LOCATIONS, SEE “DIMENSION” SECTION.

ALL GAS CONNECTIONS MUST BE CONTAINED WITHIN THE APPLIANCE WHEN COMPLETE.

HIGH PRESSURE WILL DAMAGE VALVE. DISCONNECT GAS SUPPLY PIPING BEFORE TESTING GAS

LINE AT TEST PRESSURES ABOVE 1/2 PSIG.

VALVE SETTINGS HAVE BEEN FACTORY SET, DO NOT CHANGE.

Proceed once the vent installation is complete. Installation and servicing to be done by a qualified installer

Do not use open flame.

Move the appliance into position and secure.

If equipped with a flex connector the appliance is designed to accept a 1/2” gas supply. Without the connector it is designed to accept a 3/8” gas supply. The appliance is equipped with a manual shut off valve to turn off the gas supply to the appliance.

Connect the gas supply in accordance to local codes. In the absence of local codes, install to the current CAN/CSA-B149.1 Installation Code in Canada or to the current National Fuel Gas Code, ANSI Z223.1 / NFPA 54 in the United States.

When flexing any gas line, support the gas valve so that the lines are not bent or kinked.

Check for gas leaks by brushing on a soap and water solution.

30.1

2.4OPTIONAL WALL SWITCH

For ease of accessibility, an optional remote wall switch or millivolt thermostat may be installed in a convenient location. Route a 2 strand, solid core millivolt wire from the valve to the wall switch or millivolt thermostat. The

recommended maximum lead length depends on wire size:

 

 

 

 

 

WIRE SIZE

MAX. LENGTH

1

 

 

 

 

14 gauge

100 feet

 

 

 

 

2

 

OL

N

F

16 gauge

60 feet

 

 

 

 

 

O

18 gauge

40 feet

 

 

 

 

 

 

 

 

IP

 

 

 

 

HI

O

F

 

 

 

 

 

TOL

 

 

 

3

 

 

 

 

 

P

 

 

Disconnect the existing wires from terminals 1 and 3 (from the

 

TOLI

 

 

 

 

 

 

ON/OFF switch) and replace with the leads from the wall switch / millivolt thermostat.

50.1